zoukankan      html  css  js  c++  java
  • MES生产日报存储过程

    USE [ScreenMonitor]
    GO
    /****** Object: StoredProcedure [dbo].[ImportProductForDay] Script Date: 04/11/2016 17:31:55 ******/
    SET ANSI_NULLS ON
    GO
    SET QUOTED_IDENTIFIER ON
    GO

    --=========================================
    --DESCRIPTION: 生产日报
    --exec ImportProductForDay
    -- =============================================
    ALTER PROCEDURE [dbo].[ImportProductForDay]

    as
    declare @BeginDate varchar(20),@EndDate varchar(20)
    set @BeginDate=CONVERT(varchar(10),getdate(),121)+' 08:30:00' --'2014-10-20 08:30:00'
    set @EndDate=CONVERT(varchar(19),getdate(),121) --'2014-10-24 20:29:59'

    --第一部分,基础数据来源。
    if object_id('tempdb..#tmpDispatchOrder') is not null drop table #tmpDispatchOrder
    create table #tmpDispatchOrder
    (
    --RowSeq int identity(1,1),
    MO varchar(50),
    DispatchNo varchar(50),
    DispatchPrior float,
    ProductNo varchar(50),
    MachineNo varchar(50),
    ProcCode varchar(20),
    StaCode varchar(10),
    currDate varchar(10),
    Bc varchar(10),
    BcCode varchar(10),
    BCBeginTime varchar(19),
    BCEndTime varchar(19),
    ProductName varchar(2000),
    MaterialNo varchar(50),
    BatchNo varchar(100),
    DispatchNum int,
    FactStartDate varchar(20),
    FactStopDate varchar(20),
    StandCycle decimal(18,2),
    StandEmployee int,
    SocketNum int,
    MoType int,
    ClassNum int, --班次计划数
    ProductNum int ,
    ProductQty int,
    GoodNum int,--实际合格数
    BadNum int,
    WorkTime decimal(18,4),
    NoCardTime decimal(18,4),
    TestModeTime decimal(18,4),
    StopTime decimal(18,4),
    PatrolMachineNum int,
    AdjustMacNum int,
    PolishNum int,
    BadRate varchar(100),
    BadReason varchar(8000),
    StartReading varchar(20),
    EndReading varchar(20),
    Degreeses int,
    MeterRate int,
    StrEmpName varchar(8000),
    DispatchQty int,
    Flag int
    )
    declare @r_EndDate varchar(19)
    --select @r_EndDate = CONVERT(varchar(10),dateadd(day,1,@EndDate),121)+ ' 07:59:59'

    insert into #tmpDispatchOrder(MO, DispatchNo, DispatchPrior, ProductNo,MachineNo, ProcCode,StaCode, ProductName, BatchNo, DispatchNum, BadNum, FactStartDate, FactStopDate
    , StandCycle, StandEmployee, SocketNum,MoType,DispatchQty,flag)
    select distinct a.MO, a.DispatchNo, a.DispatchPrior, a.ItemNo,a.MachineNO,a.ProcCode,b.StaCode,c.ItemName, a.LotNO, a.DispatchQty, 0, convert(char(19),a.ActualStartDate,121), convert(char(19),a.ActualEndDate,121)
    , a.StandCycle, c.StandEmployee, case a.SocketNum when 0 then 1 else a.SocketNum end SocketNum ,a.MOType,a.DispatchQty,0
    from V_DispatchOrder a
    inner join mes_machine b on a.MachineNo=b.MachineNo
    left join mes_Item c on a.ItemNo=c.ItemNo
    left join mes_MouldDetail d on a.MouldNo=d.MouldNo
    left join (select DispatchNo,MaterialNO,BatchNO from MES_Material b where b.ID=(select ID=MAX(ID) from MES_Material
    where DispatchNo=b.DispatchNO group by DispatchNO) ) m on a.DispatchNo=m.DispatchNO
    where dispatchStatus>0
    and ((ActualStartDate between @BeginDate and @EndDate )
    OR (ActualEndDate between @BeginDate and @EndDate )
    OR (ActualStartDate <= @BeginDate and ActualEndDate >= @EndDate))

    if object_id('tempdb..#tmpDispatchBc') is not null drop table #tmpDispatchBc
    create table #tmpDispatchBc
    (
    MO varchar(50),
    DispatchNo varchar(50),
    DispatchPrior float,
    ProductNo varchar(50),
    ProcCode varchar(20),
    currDate varchar(10),
    Bc varchar(10),
    BcCode varchar(10),
    BCBeginTime varchar(20),
    BCEndTime varchar(20),
    ProdBeginTime datetime,
    ProdEndTime datetime,
    CycleTime decimal(10,2),
    Flag int
    )

    if object_id('tempdb..#NoCardTime') is not null drop table #NoCardTime
    create table #NoCardTime
    (
    mo varchar(20),
    dispatchno varchar(20),
    machineno varchar(520),
    currDate varchar(10),
    BCCode varchar(10),
    Bc varchar(10),
    BCBeginTime varchar(20),
    BCEndTime varchar(20),
    TotalTime decimal(18,4),
    NoCardTime decimal(18,4),
    StopTime decimal(18,4),
    TestModeTime decimal(18,4)
    )

    declare @t_CurDate varchar(10)
    select @t_CurDate = CONVERT(varchar(10),convert(datetime,@BeginDate),121)
    while(@t_CurDate<=convert(varchar(10),convert(datetime,@EndDate),121))
    begin
    --未刷卡停机
    insert into #tmpDispatchBc(MO, DispatchNo,DispatchPrior,ProductNo,ProcCode, currDate,Bc, BcCode,BCBeginTime,BCEndTime, Flag )
    select MO, DispatchNo,DispatchPrior,ProductNo,ProcCode,@t_CurDate,'白班','AC',@t_CurDate+' 08:00:00',@t_CurDate+' 19:59:59',0
    from #tmpDispatchOrder

    insert into #NoCardTime(MachineNO, BCCode,Bc,CurrDate,BCBeginTime,BCEndTime, MO, DispatchNO)
    select MachineNo, 'BC','晚班', @t_CurDate ,@t_CurDate+' 20:00:00',CONVERT(varchar(10),dateadd(day,1,convert(datetime,@t_CurDate)),121)+' 07:59:59', '', ''
    from V_Machine --where (@MachineNo = '' or MachineNO like '%'+@MachineNo+'%')
    union
    select MachineNo, 'AC','白班', @t_CurDate ,@t_CurDate+' 08:00:00',@t_CurDate+' 19:59:59', '', ''
    from V_Machine --where (@MachineNo = '' or MachineNO like '%'+@MachineNo+'%')
    insert into #tmpDispatchBc(MO, DispatchNo,DispatchPrior,ProductNo,ProcCode,currDate,Bc, BcCode,BCBeginTime,BCEndTime,Flag)
    select MO, DispatchNo,DispatchPrior,ProductNo,ProcCode,@t_CurDate,'晚班','BC',@t_CurDate+' 20:00:00',CONVERT(varchar(10),dateadd(day,1,convert(datetime,@t_CurDate)),121)+' 07:59:59',0
    from #tmpDispatchOrder

    set @t_CurDate = CONVERT(varchar(10),dateadd(day,1,convert(datetime,@t_CurDate)),121)
    end

    --如果当前时间是白班,删除晚班的记录,因为还没到晚班
    delete from #NoCardTime where BCBeginTime >GETDATE()
    delete from #tmpDispatchBc where BCBeginTime >GETDATE()

    insert into #tmpDispatchOrder(Mo,MoType,DispatchNo,DispatchPrior,ProductNo,ProductName,MachineNo,ProcCode,StaCode,currDate,Bc,BcCode,StandCycle,SocketNum,MaterialNo,BatchNo,BCBeginTime,BCEndTime,DispatchQty,flag)
    select Mo,MoType,DispatchNo,DispatchPrior,ProductNo,ProductName,MachineNo,ProcCode,a.StaCode,currDate,Bc,BcCode,
    StandCycle,SocketNum, a.MaterialNO,a.BatchNO,BCBeginTime,BCEndTime,DispatchQty,1
    from (
    select distinct a.Mo,MoType,a.DispatchNo,a.DispatchPrior,a.ProductNo,b.ProductName,b.MachineNo,b.ProcCode,b.StaCode,a.currDate,a.Bc,c.BcCode,b.StandCycle,SocketNum=b.SocketNum,convert(varchar(19),a.BCBeginTime,121) BCBeginTime,convert(varchar(19),a.BCEndTime,121) BCEndTime
    ,b.MaterialNO
    ,b.BatchNO,b.DispatchQty
    from #tmpDispatchBc a join MES_BCDetail c on a.BcCode=c.BcCode
    inner join #tmpDispatchOrder b on a.DispatchNo=b.DispatchNo and a.DispatchPrior=b.DispatchPrior and a.ProductNo=b.ProductNo) a
    order by MachineNo, currDate,bc,DispatchNo desc,ProductNo desc

    --更新中间表已经生成的数据
    update d set ProductNum = prodqty,
    ProductQty=prodqty,
    BadNum = badqty,
    WorkTime = prodtime,
    TestModeTime=TestMouldTime,
    d.StopTime = j.StopTime,
    PatrolMachineNum=xunjiqty
    ,polishNum=damoqty,flag=2
    from #tmpDispatchOrder d join JM_Interface j on d.dispatchno=j.dispatchno and d.dispatchprior=j.dispatchprior and d.currDate=j.currDate and d.BcCode=j.BcCode
    where d.flag=1 -- RowSeq between @row_from and @row_to
    --delete from #tmpDispatchOrder_Reach where ProductNum=0 and BadNum=0 and TestModeTime=0.00 and WorkTime=0.00 and StopTime=0.00 and PatrolMachineNum=0 and PolishNum=0
    --delete from #tmpDispatchOrder_Reach where StopTime<0.00

    --计算班次所有派工单的总时间,停机时间就计算空单的停机时间
    update t1 set NoCardTime = isnull(i.NoCardTime,0.0000),totaltime=ISNULL(i.TotalTime,0)
    from #NoCardTime t1
    left join (select t.MachineNO,CurrDate,BCCode,BCBeginTime,BCEndTime, NoCardTime =(DATEDIFF(ss,BCBeginTime,BCEndTime)+1)/3600.0-Sum(TotalTime),Sum(TotalTime) TotalTime
    from (select distinct d.MachineNO, d.BCCode,d.CurrDate,d.dispatchno,d.BCBeginTime,d.BCEndTime,TotalTime=d.WorkTime+isnull(d.StopTime,0)+d.TestModeTime
    from #tmpDispatchOrder d
    where d.DispatchNO <> '' and d.Flag=2) t
    group by t.MachineNO,CurrDate,BCCode,BCBeginTime,BCEndTime
    )i on t1.MachineNO = i.MachineNO and t1.CurrDate=i.CurrDate and t1.BCCode=i.BCCode

    --更新空单的试模时间
    update d set TestModeTime=TestMouldTime,d.StopTime=j.stoptime
    from #NoCardTime d join JM_Interface j on d.currDate=j.currDate and d.MachineNO = j.MachineNO and d.BcCode=j.BcCode where d.DispatchNO='' and j.DispatchNO=''


    --更新中间表还没有生成的派工单的数据
    update d set ProductNum = dbo.FN_GetProdQty(Mo,DispatchNo,ProductNo,ProcCode,DispatchPrior, BCBeginTime,BCEndTime)+dbo.FN_GetAdjustMachineQty(Mo,DispatchNo,ProductNo,DispatchPrior, BCBeginTime, BCEndTime,'',ProcCode),
    ProductQty=(dbo.FN_GetProdQty(Mo,DispatchNo,ProductNo,ProcCode,DispatchPrior, '','')+dbo.FN_GetAdjustMachineQty(Mo,DispatchNo,ProductNo,DispatchPrior, '', '','',ProcCode))-dbo.FN_GetBadQty(Mo,DispatchNo,ProductNo,ProcCode,DispatchPrior, '', '')-dbo.FN_GetPatrolMachineOrPolishQty(MO,DispatchNo,ProductNo,ProcCode,DispatchPrior,'', '',2),
    BadNum = dbo.FN_GetBadQty(Mo,DispatchNo,ProductNo,ProcCode,DispatchPrior, BCBeginTime, BCEndTime),
    AdjustMacNum = dbo.FN_GetAdjustMachineQty(Mo,DispatchNo,ProductNo,DispatchPrior, BCBeginTime, BCEndTime,'',ProcCode),
    WorkTime = dbo.FN_GetProductTime(mo,DispatchNo,ProcCode,DispatchPrior,BCBeginTime, BCEndTime),
    --TestModeTime=case when MoType=2 then dbo.FN_GetProductTime(mo,DispatchNo,ProcCode,DispatchPrior,BCBeginTime, BCEndTime) else 0 end,
    TestModeTime=dbo.FN_GetTestModeTime(Mo,DispatchNo,ProcCode,DispatchPrior,BCBeginTime, BCEndTime),
    StopTime = dbo.FN_GetStopTime(Mo,DispatchNo,ProcCode,DispatchPrior, BCBeginTime, BCEndTime),
    PatrolMachineNum=dbo.FN_GetPatrolMachineOrPolishQty(MO,DispatchNo,ProductNo,ProcCode,DispatchPrior,BCBeginTime, BCEndTime,2)
    ,polishNum=dbo.FN_GetPolishQty(MO,DispatchNo,ProductNo,ProcCode,DispatchPrior,BCBeginTime, BCEndTime),flag=2
    from #tmpDispatchOrder d
    where d.flag=1 and GETDATE() between BCBeginTime and BCEndTime


    -- update t1 set totaltime=ISNULL(i.TotalTime,0),TestModeTime=dbo.FN_GetStopReasonTimeByMach2(t1.MachineNO,44, t1.BCBeginTime, t1.BCEndTime), StopTime=dbo.FN_GetStopTimeByMachine2(t1.MachineNO, t1.BCBeginTime, t1.BCEndTime)
    -- from #NoCardTime t1
    -- left join (select t.MachineNO,CurrDate,BCCode,BCBeginTime,BCEndTime,Sum(TotalTime) TotalTime
    -- from (select distinct MachineNO, BCCode,CurrDate,dispatchno,BCBeginTime,BCEndTime, TotalTime=WorkTime+StopTime+TestModeTime
    -- from #tmpDispatchOrder
    -- where isnull(DispatchNO,'') <> '' and flag=2 and GETDATE() between BCBeginTime and BCEndTime) t
    -- group by t.MachineNO,CurrDate,BCCode,BCBeginTime,BCEndTime
    -- )i on t1.MachineNO = i.MachineNO and t1.CurrDate=i.CurrDate and t1.BCCode=i.BCCode where GETDATE() between t1.BCBeginTime and t1.BCEndTime

    --update #NoCardTime set StopTime=dbo.FN_GetStopTimeByMachine3(MachineNO, BCBeginTime, BCEndTime),TestModeTime=dbo.FN_GetStopReasonTimeByMach(MachineNO,44, BCBeginTime, BCEndTime) where totaltime=0.0000 and GETDATE() between BCBeginTime and BCEndTime
    --insert into #tmpDispatchOrder(MachineNO, BCCode,Bc, CurrDate, MO, DispatchNO,NoCardTime,TestModeTime,StopTime,BCBeginTime,BCEndTime,flag) select MachineNO, BCCode,Bc, CurrDate, MO, DispatchNO,12.0000-TotalTime-StopTime-TestModeTime,TestModeTime,StopTime,BCBeginTime,BCEndTime,2 from #NoCardTime

    if object_id('tempdb..#tmpDispatchOrder1') is not null drop table #tmpDispatchOrder1
    create table #tmpDispatchOrder1
    (
    RowSeq int identity(1,1),
    MO varchar(50),
    DispatchNo varchar(50),
    DispatchPrior float,
    ProductNo varchar(50),
    MachineNo varchar(50),
    ProcCode varchar(20),
    StaCode varchar(10),
    currDate varchar(10),
    Bc varchar(10),
    BcCode varchar(10),
    BCBeginTime varchar(19),
    BCEndTime varchar(19),
    ProductName varchar(2000),
    MaterialNo varchar(50),
    BatchNo varchar(100),
    DispatchNum int,
    FactStartDate varchar(20),
    FactStopDate varchar(20),
    StandCycle decimal(18,2),
    StandEmployee int,
    SocketNum int,
    MoType int,
    ClassNum int, --班次计划数
    ProductNum int ,
    ProductQty int,
    GoodNum int,--实际合格数
    BadNum int,
    WorkTime decimal(18,4),
    NoCardTime decimal(18,4),
    TestModeTime decimal(18,4),
    StopTime decimal(18,4),
    PatrolMachineNum int,
    AdjustMacNum int,
    PolishNum int,
    BadRate varchar(100),
    BadReason varchar(8000),
    StartReading varchar(20),
    EndReading varchar(20),
    Degreeses int,
    MeterRate int,
    StrEmpName varchar(8000),
    DispatchQty int
    )

    insert into #tmpDispatchOrder1(MO,DispatchNo,DispatchPrior,ProductNo,MachineNo,ProcCode,StaCode,currDate,Bc,BcCode,BCBeginTime,BCEndTime, ProductName,
    MaterialNo,BatchNo,DispatchNum,FactStartDate,FactStopDate,StandCycle,StandEmployee,SocketNum,MoType,ClassNum,ProductNum,ProductQty,
    GoodNum,BadNum, WorkTime,NoCardTime,TestModeTime,StopTime,PatrolMachineNum,AdjustMacNum,PolishNum,BadRate,BadReason,StartReading,EndReading,Degreeses,MeterRate,StrEmpName,DispatchQty)
    select MO,DispatchNo,DispatchPrior,ProductNo,MachineNo,ProcCode,StaCode,currDate,Bc,BcCode,BCBeginTime,BCEndTime, ProductName,
    MaterialNo,BatchNo,DispatchNum,FactStartDate,FactStopDate,StandCycle,StandEmployee,SocketNum,MoType,ClassNum,ProductNum,ProductQty,
    GoodNum,BadNum, WorkTime,NoCardTime,TestModeTime,StopTime,PatrolMachineNum,AdjustMacNum,PolishNum,BadRate,BadReason,StartReading,EndReading,Degreeses,MeterRate,StrEmpName,DispatchQty from
    #tmpDispatchOrder where Flag=2 order by MachineNo, currDate,bc,DispatchNo desc,ProductNo desc

    declare @row_from int, @row_to int
    --select @out_total_rows = count(*) from #tmpDispatchOrder1
    --execute st_MES_RS_Pages @out_total_rows, @in_pagesize, @in_page, @row_from output, @row_to output

    update #tmpDispatchOrder1 set ClassNum=CASE WHEN StandCycle = 0 THEN 0 ELSE Ceiling(CAST((WorkTime+StopTime)*3600/
    CONVERT(decimal(18,2), StandCycle) *isnull(SocketNum,1) AS decimal(18,4)))END, ProductQty=ProductQty,ProductNum=ProductNum,GoodNum=ProductNum-BadNum-PatrolMachineNum
    --,PatrolMachineNum=case when ProductNum>PatrolMachineNum then PatrolMachineNum else 0 end
    --where RowSeq between @row_from and @row_to

    update #tmpDispatchOrder1 set BadRate=CASE WHEN ProductNum = 0 THEN '0.00%' ELSE rtrim(ltrim(cast(CAST(BadNum/
    CONVERT(decimal(18,2),ProductNum)*100 AS decimal(10,2)) as char)))+'%' END
    --where RowSeq between @row_from and @row_to

    declare @tMo varchar(20),@tDispatchNo varchar(50),@tDispatchPrior float,@tProductNo varchar(50),@tProcCode varchar(20),@tcurrDate varchar(50),@tBc varchar(20),@BCBeginTime varchar(20),
    @BCEndTime varchar(20),@tBeginDate varchar(20), @tEndDate varchar(20),@tBadNum int ,@tBadText varchar(8000),@tProductNum int,@QCBillNoList varchar(8000),
    @tEmpID varchar(8000),@tEmpName varchar(8000),@iEmpID varchar(10),@iBadNum int,@iBadText varchar(8000),@iEmpName varchar(50),@iQCBillNO varchar(50),@Machine varchar(50)
    declare tmpCur cursor for
    select Mo,DispatchNo,DispatchPrior,ProductNo,ProcCode,currDate,BCBeginTime,BCEndTime,bc,MachineNo from #tmpDispatchOrder1 --where RowSeq between @row_from and @row_to
    OPEN tmpCur
    FETCH next FROM tmpCur INTO @tMo, @tDispatchNo,@tDispatchPrior,@tProductNo,@tProcCode,@tcurrDate,@BCBeginTime,@BCEndTime,@tBc,@Machine
    while @@fetch_status=0
    begin
    select @tBadNum=0,@tProductNum=0,@tBadText='',@tBeginDate='',@tEndDate='',@tEmpID='',@tEmpName='',@QCBillNoList=''
    select @tBeginDate=@BCBeginTime,
    @tEndDate=@BCEndTime
    if object_id('tempdb..#tmpQC') is not null drop table #tmpQC
    select a.QCBillNO into #tmpQC
    from mes_QC a
    join mes_qcdetail q on q.qcbillno=a.qcbillno
    left join sys_pubcode p on p.fieldvalue=badreasonid and fieldname='ddl_BadReason'
    where a.QCDate BETWEEN @tBeginDate AND @tEndDate
    and a.DispatchNo=@tDispatchNo and a.ProcCode=@tProcCode and a.ItemNO=@tProductNo
    declare tmpCur2 cursor for
    select distinct QCBillNO from #tmpQC
    open tmpCur2
    fetch next from tmpCur2 into @iQCBillNO
    while @@fetch_status=0
    begin
    set @QCBillNoList=case when @QCBillNoList='' then @QCBillNoList+@iQCBillNO else @QCBillNoList+','+@iQCBillNO end

    fetch next from tmpCur2 into @iQCBillNO
    end

    set @tBadText=(select dbo.FN_GetQCQueryClassType(@QCBillNoList))--Add by zhuss
    deallocate tmpCur2

    update #tmpDispatchOrder1 set BadReason=@tBadText where DispatchNo=@tDispatchNo and ProductNo=@tProductNo and ProcCode=@tProcCode and currDate=@tcurrDate and Bc=@tBc
    update #tmpDispatchOrder1 set StrEmpName=dbo.FN_GetEmpNameByMachineNoAndBc(@Machine,@BCBeginTime,@BCEndTime)
    where DispatchNo=@tDispatchNo and ProductNo=@tProductNo and ProcCode=@tProcCode and currDate=@tcurrDate and Bc=@tBc

    -- /*2014.9.1 hz 添加开始读数,结束读数,度数,电表倍率字段*/
    --declare @StartElecNum varchar(20),@EndElecNum varchar(20),@Tmpcount int,@NoCardcount int
    --set @StartElecNum='F'
    --set @EndElecNum='F'

    --select @Tmpcount=COUNT(*) from MES_ElecDetail a inner join #tmpDispatchBc b on a.MO=b.MO and a.DispatchNo=b.DispatchNo and a.DispatchPrior=b.DispatchPrior
    -- and a.ProcCode=b.ProcCode where a.MachineNo=@Machine and InputDate between @BCBeginTime and @BCEndTime
    -- if(@Tmpcount >1)
    -- begin
    -- select top 1 @StartElecNum=ElecNum from MES_ElecDetail a inner join #tmpDispatchBc b on a.MO=b.MO and a.DispatchNo=b.DispatchNo and a.DispatchPrior=b.DispatchPrior
    -- and a.ProcCode=b.ProcCode where a.MachineNo=@Machine and InputDate between @BCBeginTime and @BCEndTime order by InputDate
    -- select top 1 @EndElecNum=ElecNum from MES_ElecDetail a inner join #tmpDispatchBc b on a.MO=b.MO and a.DispatchNo=b.DispatchNo and a.DispatchPrior=b.DispatchPrior
    -- and a.ProcCode=b.ProcCode where a.MachineNo=@Machine and InputDate between @BCBeginTime and @BCEndTime order by InputDate desc
    -- end
    --else
    -- begin
    -- select top 1 @StartElecNum=ElecNum from MES_ElecDetail a inner join #tmpDispatchBc b on a.MO=b.MO and a.DispatchNo=b.DispatchNo and a.DispatchPrior=b.DispatchPrior
    -- and a.ProcCode=b.ProcCode where a.MachineNo=@Machine and InputDate between @BCBeginTime and @BCEndTime order by InputDate
    -- end

    --update d set StartReading=@StartElecNum,EndReading=@EndElecNum,Degreeses=case when @StartElecNum<>'F' and @EndElecNum<>'F'
    -- then case when (CONVERT(int,@EndElecNum)-CONVERT(int,@StartElecNum))<0
    -- then 0 else (CONVERT(int,@EndElecNum)-CONVERT(int,@StartElecNum)) end
    -- end,MeterRate=80
    -- from #tmpDispatchOrder1 d where MachineNo=@Machine and d.Bc=@tBc and currDate=@tcurrDate

    --select @NoCardcount=COUNT(*) from MES_ElecDetail a inner join #NoCardTime b on a.MachineNo=b.machineno where a.MachineNo=@Machine and InputDate between @BCBeginTime and @BCEndTime
    --if(@NoCardcount >1)
    -- begin
    -- select top 1 @StartElecNum=ElecNum from MES_ElecDetail a inner join #NoCardTime b on a.MachineNo=b.machineno where a.MachineNo=@Machine and InputDate between @BCBeginTime and @BCEndTime order by InputDate
    -- select top 1 @EndElecNum=ElecNum from MES_ElecDetail a inner join #NoCardTime b on a.MachineNo=b.machineno where a.MachineNo=@Machine and InputDate between @BCBeginTime and @BCEndTime order by InputDate desc
    -- end
    --else
    -- begin
    -- print 1
    -- select top 1 @StartElecNum=ElecNum from MES_ElecDetail a inner join #NoCardTime b on a.MachineNo=b.machineno where a.MachineNo=@Machine and InputDate between @BCBeginTime and @BCEndTime order by InputDate
    -- end

    --update d set StartReading=@StartElecNum,EndReading=@EndElecNum,Degreeses=case when @StartElecNum<>'F' and @EndElecNum<>'F'
    -- then case when (CONVERT(int,@EndElecNum)-CONVERT(int,@StartElecNum))<0
    -- then 0 else (CONVERT(int,@EndElecNum)-CONVERT(int,@StartElecNum)) end
    -- end,MeterRate=80
    -- from #tmpDispatchOrder1 d where MachineNo=@Machine and d.Bc=@tBc and currDate=@tcurrDate

    --update #tmpDispatchOrder1 set StartReading=null,EndReading=null,Degreeses=null,MeterRate=null where MachineNo =@Machine and Bc=@tBc and currDate=@tcurrDate and RowSeq<(select top 1 RowSeq from #tmpDispatchOrder1 where MachineNo =@Machine and Bc=@tBc and currDate=@tcurrDate order by RowSeq desc)
    /*2014.9.1 end*/

    FETCH next FROM tmpCur INTO @tMo, @tDispatchNo,@tDispatchPrior,@tProductNo,@tProcCode,@tcurrDate,@BCBeginTime,@BCEndTime,@tBc,@Machine
    END
    CLOSE tmpCur
    DEALLOCATE tmpCur

    --select ROW_NUMBER() OVER(ORDER BY MachineNo asc ) ID,Bc,StaCode,MachineNo,MO,DispatchNo,ProductNo,ProductName,currDate,MaterialNo,BatchNo,ProductNum,GoodNum,BadNum,
    --PolishNum,PatrolMachineNum,WorkTime,NoCardTime,TestModeTime,StopTime,BadRate,BadReason,StartReading,EndReading,Degreeses,MeterRate,StrEmpName
    -- from #tmpDispatchOrder1 where RowSeq between @row_from and @row_to
    select ROW_NUMBER() OVER(ORDER BY MachineNo asc ) ID,Bc,MachineNo,StrEmpName,ProductNo,ProductName,currDate,DispatchQty,ProductQty,GoodNum,BadNum,BadRate,BadReason,BCBeginTime,BCEndTime
    from #tmpDispatchOrder1 --where RowSeq between @row_from and @row_to

    --select TotalRows = @out_total_rows

  • 相关阅读:
    团队冲刺六
    团队冲刺五
    【Mybaits学习】03_ CRUD基于注解
    【Mybaits学习】02_ 快速入门
    【Mybaits学习】01_ 初识
    深圳国际马拉松
    深圳南山半程马拉松
    Selenide使用笔记
    UI自动化测试01-环境搭建
    Java C3p0在Spring中运用
  • 原文地址:https://www.cnblogs.com/chengjun/p/5381576.html
Copyright © 2011-2022 走看看