zoukankan      html  css  js  c++  java
  • smartd

    smartd是一个守护进程(一个帮助程序),它能监视拥有自我监视,分析和汇报技术(Self-Monitoring, Analysis, and Reporting Technology - SMART)的硬盘。
    SMART系统使得硬盘能监视并汇报自己的运行状况。它的一个重要特性是能够预测失败,使得系统管理员能避免数据丢失。
    smartd由kernel-utils包缺省安装。用命令 rpm -ql kernel-utils 可以列出kernel-utils包中的文件。
    smartd守护进程通常在系统启动的时候被开启,它的配置文件是/etc/smartd.conf。
    比如,假设有两个硬盘被安装,/dev/hda和/dev/hdb。一个是CD_ROM设备,另一个是硬盘。为了检测它们是否支持SMART,使用命令 smartctl -i /dev/hda 和 smartctl -i /dev/hdb:
    # /usr/sbin/smartctl -i /dev/hda
    smartctl version 5.1-11 Copyright (C) 2002-3 Bruce Allen
    Home page is http://smartmontools.sourceforge.net/
     
    === START OF INFORMATION SECTION ===
    Device Model:     ST380011A
    Serial Number:    3JVB672N
    Firmware Version: 8.01
    Device is:        Not in smartctl database [for details use: -P showall]
    ATA Version is:   6
    ATA Standard is:  ATA/ATAPI-6 T13 1410D revision 2
    Local Time is:    Fri Aug 20 14:09:16 2004 EST
    SMART support is: Available - device has SMART capability.
    SMART support is: Enabled
    ”SMART support is: Available - device has SMART capability.“这行说明支持SMART。"SMART support is: Enabled”这行说明SMART已经被打开。
    CD-ROM设备和旧式的硬盘不支持SMART,这可以从smartctl -i /dev/hdb的输出看出:
    # /usr/sbin/smartctl -i /dev/hdb
    smartctl version 5.1-11 Copyright (C) 2002-3 Bruce Allen
    Home page is http://smartmontools.sourceforge.net/
     
    === START OF INFORMATION SECTION ===
    Device Model:     LTN526D
    Serial Number:    [No Information Found]
    Firmware Version: 9S03
    Device is:        Not in smartctl database [for details use: -P showall]
    ATA Version is:   1
    ATA Standard is:  Exact ATA specification draft version not indicated
    Local Time is:    Fri Aug 20 14:24:43 2004 EST
    SMART is only available in ATA Version 3 Revision 3 or greater.
    We will try to proceed in spite of this.
    SMART support is: Unavailable - device lacks SMART capability.
    A mandatory SMART command has failed: exiting. To continue, use the -T
     option to set the tolerance level to 'permissive'
    注意有些硬盘控制器不支持SMART。比如有些硬件RAID控制器不支持,或者不会传递SMART信息,即使加入的硬盘支持SMART。
    可以修改/etc/smartctl.conf文件,使得smartd只监视你想监视的设备。假设只有/dev/hda需要被监视,在该设备上如果有警告信息发生,需要把它发给根用户,那么/etc/smartd.conf需要这样修改:
    # /etc/smartd.conf
    # Sample configuration file for smartd.  See man 5 smartd.conf.
    # Home page is: http://smartmontools.sourceforge.net
    ...
    # A very silent check.  Only report SMART health status if it fails
    # But send an email in this case
    /dev/hda -a -m root@localhost.localdomain ...
    编辑完/etc/smartd.conf,重启该守护进程:
    # /sbin/service smartd restart
    Shutting down smartd:                                      [FAILED]
    Starting smartd:                                           [  OK  ]


    要设置smartd在系统启动时候被激活,在根用户下用 chkconfig smartd on 命令。