zoukankan      html  css  js  c++  java
  • storcli64 查看raid

    [root@localhost ~]# ./storcli64 show ctrlcount  ---查看raid数量
    Status Code = 0
    Status = Success
    Description = None
    
    Controller Count = 1
    
    
    [root@localhost ~]#
    [root@localhost ~]# ./storcli64  /c0 /v0 show   ---查看raid结构,虚拟硬盘
    Controller = 0
    Status = Success
    Description = None
    
    
    Virtual Drives :
    ==============
    
    ---------------------------------------------------------------
    DG/VD TYPE  State Access Consist Cache Cac sCC       Size Name 
    ---------------------------------------------------------------
    0/0   RAID0 Optl  RW     Yes     RWTD  -   ON  446.625 GB      
    ---------------------------------------------------------------
    
    Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded
    Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady|B=Blocked|
    Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
    AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
    Check Consistency
    
    
    
    [root@localhost ~]#
    [root@localhost ~]# ./storcli64 /c0 /eall /sall show  ---查看物理硬盘
    Controller = 0
    Status = Success
    Description = Show Drive Information Succeeded.
    
    
    Drive Information :
    =================
    
    ----------------------------------------------------------------------------
    EID:Slt DID State DG       Size Intf Med SED PI SeSz Model               Sp 
    ----------------------------------------------------------------------------
    8:0      11 JBOD  -    3.637 TB SATA HDD N   N  512B ST4000NM000A-2HZ100 U  
    8:1       9 JBOD  -    3.637 TB SATA HDD N   N  512B ST4000NM000A-2HZ100 U  
    8:12     21 JBOD  -  446.625 GB SATA SSD N   N  512B Maxtor Z1 SSD 480GB U  
    8:13     22 Onln  0  446.625 GB SATA SSD N   N  512B Maxtor Z1 SSD 480GB U  
    ----------------------------------------------------------------------------
    
    EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
    DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
    UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
    Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
    SeSz-Sector Size|Sp-Spun|U-Up|D-Down/PowerSave|T-Transition|F-Foreign
    UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
    CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded
    
    
    
    [root@localhost ~]# lsblk
    NAME            MAJ:MIN RM   SIZE RO TYPE MOUNTPOINT
    sda               8:0    0   3.7T  0 disk 
    ├─sda1            8:1    0   200M  0 part 
    ├─sda2            8:2    0     1G  0 part 
    └─sda3            8:3    0 445.4G  0 part 
      ├─klas-swap   252:2    0     4G  0 lvm  
      └─klas-root   252:3    0 441.4G  0 lvm  
    sdb               8:16   0   3.7T  0 disk 
    ├─sdb1            8:17   0   1.9T  0 part 
    ├─sdb2            8:18   0   1.3T  0 part 
    └─sdb4            8:20   0   1.6T  0 part 
    sdc               8:32   0 447.1G  0 disk 
    sdd               8:48   0 446.6G  0 disk 
    ├─sdd1            8:49   0   200M  0 part /boot/efi
    ├─sdd2            8:50   0     1G  0 part /boot
    └─sdd3            8:51   0 445.4G  0 part 
      ├─klas00-root 252:0    0 441.4G  0 lvm  /
      └─klas00-swap 252:1    0     4G  0 lvm  [SWAP]
    sr0              11:0    1  1024M  0 rom  
    sr1              11:1    1  1024M  0 rom  
    sr2              11:2    1  1024M  0 rom  
    sr3              11:3    1  1024M  0 rom  
    [root@localhost ~]#
    [root@localhost ~]# ./storcli64 show all
    Segmentation fault (core dumped)
    [root@localhost ~]# ./storcli64 /c0 show all
    Generating detailed summary of the adapter, it may take a while to complete.
    
    Controller = 0
    Status = Failure
    Description = None
    
    Detailed Status :
    ===============
    
    ------------------------------------------------
    Ctrl Status ErrCd ErrMsg                        
    ------------------------------------------------
       0 Failed   255 Failed to get Bus Information 
    ------------------------------------------------
    
    
    
    Basics :
    ======
    Controller = 0
    Model = AVAGO MegaRAID SAS 9361-8i 2GB
    Serial Number = SK84171618
    Current Controller Date/Time = 09/05/2019, 09:28:34
    Current System Date/time = 09/05/2019, 17:28:34
    SAS Address = 500605b00ece47f0
    PCI Address = NA
    Mfg Date = 10/12/18
    Rework Date = 00/00/00
    Revision No = 22002
    
    
    Version :
    =======
    Firmware Package Build = 24.21.0-0017
    Firmware Version = 4.680.00-8274
    CPLD Version = 26747-01A
    Bios Version = 6.36.00.1_4.19.08.00_0x06180202
    HII Version = 03.25.05.03
    Ctrl-R Version = 5.19-0601
    Preboot CLI Version = 01.07-05:#%0000
    NVDATA Version = 3.1705.00-0005
    Boot Block Version = 3.07.00.00-0003
    Driver Name = megaraid_sas
    Driver Version = 07.706.03.00-rc1
    
    
    Bus :
    ===
    Vendor Id = 0x1000
    Device Id = 0x5D
    SubVendor Id = 0x1000
    SubDevice Id = 0x9361
    Host Interface = PCI-E
    Device Interface = SAS-12G
    
    
    Pending Images in Flash :
    =======================
    Image name = No pending images
    
    
    Status :
    ======
    Controller Status = Optimal
    Memory Correctable Errors = 0
    Memory Uncorrectable Errors = 0
    ECC Bucket Count = 0
    Any Offline VD Cache Preserved = No
    BBU Status = NA
    PD Firmware Download in progress = No
    Lock Key Assigned = No
    Failed to get lock key on bootup = No
    Lock key has not been backed up = No
    Bios was not detected during boot = No
    Controller must be rebooted to complete security operation = No
    A rollback operation is in progress = No
    At least one PFK exists in NVRAM = Yes
    SSC Policy is WB = No
    Controller has booted into safe mode = No
    Current Personality = RAID-Mode
    
    
    Supported Adapter Operations :
    ============================
    Rebuild Rate = Yes
    CC Rate = Yes
    BGI Rate  = Yes
    Reconstruct Rate = Yes
    Patrol Read Rate = Yes
    Alarm Control = Yes
    Cluster Support = No
    BBU  = Yes
    Spanning = Yes
    Dedicated Hot Spare = Yes
    Revertible Hot Spares = Yes
    Foreign Config Import = Yes
    Self Diagnostic = Yes
    Allow Mixed Redundancy on Array = No
    Global Hot Spares = Yes
    Deny SCSI Passthrough = No
    Deny SMP Passthrough = No
    Deny STP Passthrough = No
    Support more than 8 Phys = Yes
    FW and Event Time in GMT = No
    Support Enhanced Foreign Import = Yes
    Support Enclosure Enumeration = Yes
    Support Allowed Operations = Yes
    Abort CC on Error = Yes
    Support Multipath = Yes
    Support Odd & Even Drive count in RAID1E = No
    Support Security = No
    Support Config Page Model = Yes
    Support the OCE without adding drives = Yes
    Support EKM = No
    Snapshot Enabled = No
    Support PFK = Yes
    Support PI = Yes
    Support LDPI Type1 = No
    Support LDPI Type2 = No
    Support LDPI Type3 = No
    Support Ld BBM Info = No
    Support Shield State = Yes
    Block SSD Write Disk Cache Change = Yes
    Support Suspend Resume BG ops = Yes
    Support Emergency Spares = Yes
    Support Set Link Speed = Yes
    Support Boot Time PFK Change = No
    Support JBOD = Yes
    Disable Online PFK Change = No
    Support Perf Tuning = Yes
    Support SSD PatrolRead = Yes
    Real Time Scheduler = Yes
    Support Reset Now = Yes
    Support Emulated Drives = Yes
    Headless Mode = Yes
    Dedicated HotSpares Limited = No
    Point In Time Progress = Yes
    Extended LD = Yes
    Boot Volume Supported = No
    Support Uneven span  = No
    Support Config Auto Balance = No
    Support Maintenance Mode = No
    Support Diagnostic results = Yes
    Support Ext Enclosure = Yes
    Support Sesmonitoring = Yes
    Support SecurityonJBOD = Yes
    Support ForceFlash = Yes
    Support DisableImmediateIO = Yes
    Support LargeIOSupport = Yes
    Support DrvActivityLEDSetting = Yes
    Support FlushWriteVerify = Yes
    Support CPLDUpdate = Yes
    Support ForceTo512e = Yes
    Support discardCacheDuringLDDelete = Yes
    Support JBOD Write cache = No
    Support Large QD Support = No
    Support Ctrl Info Extended = No
    Support IButton less = No
    Support AES Encryption Algorithm = No
    Support Encrypted MFC = No
    
    
    Supported PD Operations :
    =======================
    Force Online = Yes
    Force Offline = Yes
    Force Rebuild = Yes
    Deny Force Failed = No
    Deny Force Good/Bad = No
    Deny Missing Replace = No
    Deny Clear = No
    Deny Locate = No
    Support Power State = Yes
    Set Power State For Cfg = No
    Support T10 Power State = No
    Support Temperature = Yes
    NCQ = Yes
    Support Max Rate SATA = No
    Support Degraded Media = No
    Support Parallel FW Update = Yes
    Support Drive Crypto Erase = Yes
    
    
    Supported VD Operations :
    =======================
    Read Policy = Yes
    Write Policy = Yes
    IO Policy = Yes
    Access Policy = Yes
    Disk Cache Policy = Yes
    Reconstruction = Yes
    Deny Locate = No
    Deny CC = No
    Allow Ctrl Encryption = No
    Enable LDBBM = Yes
    Support FastPath = Yes
    Performance Metrics = Yes
    Power Savings = No
    Support Powersave Max With Cache = No
    Support Breakmirror = Yes
    Support SSC WriteBack = No
    Support SSC Association = No
    Support VD Hide = Yes
    Support VD Cachebypass = Yes
    Support VD discardCacheDuringLDDelete = Yes
    
    
    Advanced Software Option :
    ========================
    
    ----------------------------------------
    Adv S/W Opt        Time Remaining  Mode 
    ----------------------------------------
    MegaRAID FastPath  Unlimited       -    
    MegaRAID RAID6     Unlimited       -    
    MegaRAID RAID5     Unlimited       -    
    ----------------------------------------
    
    Safe ID =  NSHHBGAKBJNNVM68G96T5LJB8PDMFXGPPBM3Q9AZ
    
    HwCfg :
    =====
    ChipRevision =  C0
    BatteryFRU = N/A
    Front End Port Count = 0
    Backend Port Count = 8
    BBU = Absent
    Alarm = On
    Serial Debugger = Present
    NVRAM Size = 32KB
    Flash Size = 16MB
    On Board Memory Size = 2048MB
    CacheVault Flash Size = NA
    TPM = Absent
    Upgrade Key = Absent
    On Board Expander = Absent
    Temperature Sensor for ROC = Present
    Temperature Sensor for Controller = Absent
    Upgradable CPLD = Present
    Current Size of CacheCade (GB) = 0
    Current Size of FW Cache (MB) = 1715
    ROC temperature(Degree Celsius) = 68
    
    
    Policies :
    ========
    
    Policies Table :
    ==============
    
    ------------------------------------------------
    Policy                          Current Default 
    ------------------------------------------------
    Predictive Fail Poll Interval   300 sec         
    Interrupt Throttle Active Count 16              
    Interrupt Throttle Completion   50 us           
    Rebuild Rate                    30 %    30%     
    PR Rate                         30 %    30%     
    BGI Rate                        30 %    30%     
    Check Consistency Rate          30 %    30%     
    Reconstruction Rate             30 %    30%     
    Cache Flush Interval            4s              
    ------------------------------------------------
    
    Flush Time(Default) = 4s
    Drive Coercion Mode = none
    Auto Rebuild = On
    Battery Warning = On
    ECC Bucket Size = 15
    ECC Bucket Leak Rate (hrs) = 24
    Restore HotSpare on Insertion = Off
    Expose Enclosure Devices = On
    Maintain PD Fail History = Off
    Reorder Host Requests = On
    Auto detect BackPlane = SGPIO/i2c SEP
    Load Balance Mode = Auto
    Security Key Assigned = Off
    Disable Online Controller Reset = Off
    Use drive activity for locate = Off
    
    
    Boot :
    ====
    BIOS Enumerate VDs = 1
    Stop BIOS on Error = Off
    Delay during POST = 0
    Spin Down Mode = None
    Enable Ctrl-R = Yes
    Enable Web BIOS = No
    Enable PreBoot CLI = No
    Enable BIOS = Yes
    Max Drives to Spinup at One Time = 2
    Maximum number of direct attached drives to spin up in 1 min = 10
    Delay Among Spinup Groups (sec) = 12
    Allow Boot with Preserved Cache = Off
    
    
    High Availability :
    =================
    Topology Type = None
    Cluster Permitted = No
    Cluster Active = No
    
    
    Defaults :
    ========
    Phy Polarity = 0
    Phy PolaritySplit = 0
    Strip Size = 256 KB
    Write Policy = WB
    Read Policy = RA
    Cache When BBU Bad = Off
    Cached IO = Off
    VD PowerSave Policy = Controller Defined
    Default spin down time (mins) = 30
    Coercion Mode = None
    ZCR Config = Unknown
    Max Chained Enclosures = 16
    Direct PD Mapping = No
    Restore Hot Spare on Insertion = No
    Expose Enclosure Devices = Yes
    Maintain PD Fail History = Yes
    Zero Based Enclosure Enumeration = No
    Disable Puncturing = No
    EnableLDBBM = Yes
    DisableHII = No
    Un-Certified Hard Disk Drives = Allow
    SMART Mode = Mode 6
    Enable LED Header = Yes
    LED Show Drive Activity = Yes
    Dirty LED Shows Drive Activity = No
    EnableCrashDump = Yes
    Disable Online Controller Reset = No
    Treat Single span R1E as R10 = No
    Power Saving option = Enabled
    TTY Log In Flash = No
    Auto Enhanced Import = Yes
    BreakMirror RAID Support = Yes
    Disable Join Mirror = Yes
    Enable Shield State = Yes
    Time taken to detect CME = 60 sec
    
    
    Capabilities :
    ============
    Supported Drives = SAS, SATA
    Boot Volume Supported = NO
    RAID Level Supported = RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50
    , RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, 
    PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span
    Enable JBOD = Yes
    Mix in Enclosure = Allowed
    Mix of SAS/SATA of HDD type in VD = Allowed
    Mix of SAS/SATA of SSD type in VD = Allowed
    Mix of SSD/HDD in VD = Allowed
    SAS Disable = No
    Max Arms Per VD = 32
    Max Spans Per VD = 8
    Max Arrays = 128
    Max VD per array = 16
    Max Number of VDs = 64
    Max Parallel Commands = 928
    Max SGE Count = 60
    Max Data Transfer Size = 8192 sectors
    Max Strips PerIO = 128
    Max Configurable CacheCade Size(GB) = 0
    Max Transportable VDs = 0
    Min Strip Size = 64 KB
    Max Strip Size = 1.0 MB
    
    
    Scheduled Tasks :
    ===============
    Consistency Check Reoccurrence = 168 hrs
    Next Consistency check launch = 08/08/2020, 03:00:00
    Patrol Read Reoccurrence = 168 hrs
    Next Patrol Read launch = 08/08/2020, 03:00:00
    Battery learn Reoccurrence = NA
    Next Battery Learn = NA
    OEMID = AVAGO
    
    Drive Groups = 1
    
    TOPOLOGY :
    ========
    
    -----------------------------------------------------------------------------
    DG Arr Row EID:Slot DID Type  State BT       Size PDC  PI SED DS3  FSpace TR 
    -----------------------------------------------------------------------------
     0 -   -   -        -   RAID0 Optl  N  446.625 GB dflt N  N   none N      N  
     0 0   -   -        -   RAID0 Optl  N  446.625 GB dflt N  N   none N      N  
     0 0   0   8:13     22  DRIVE Onln  N  446.625 GB dflt N  N   none -      N  
    -----------------------------------------------------------------------------
    
    DG=Disk Group Index|Arr=Array Index|Row=Row Index|EID=Enclosure Device ID
    DID=Device ID|Type=Drive Type|Onln=Online|Rbld=Rebuild|Dgrd=Degraded
    Pdgd=Partially degraded|Offln=Offline|BT=Background Task Active
    PDC=PD Cache|PI=Protection Info|SED=Self Encrypting Drive|Frgn=Foreign
    DS3=Dimmer Switch 3|dflt=Default|Msng=Missing|FSpace=Free Space Present
    TR=Transport Ready
    
    Virtual Drives = 1
    
    VD LIST :
    =======
    
    ---------------------------------------------------------------
    DG/VD TYPE  State Access Consist Cache Cac sCC       Size Name 
    ---------------------------------------------------------------
    0/0   RAID0 Optl  RW     Yes     RWTD  -   ON  446.625 GB      
    ---------------------------------------------------------------
    
    Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded
    Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady|B=Blocked|
    Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
    AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
    Check Consistency
    
    Physical Drives = 4
    
    PD LIST :
    =======
    
    ----------------------------------------------------------------------------
    EID:Slt DID State DG       Size Intf Med SED PI SeSz Model               Sp 
    ----------------------------------------------------------------------------
    8:0      11 JBOD  -    3.637 TB SATA HDD N   N  512B ST4000NM000A-2HZ100 U  
    8:1       9 JBOD  -    3.637 TB SATA HDD N   N  512B ST4000NM000A-2HZ100 U  
    8:12     21 JBOD  -  446.625 GB SATA SSD N   N  512B Maxtor Z1 SSD 480GB U  
    8:13     22 Onln  0  446.625 GB SATA SSD N   N  512B Maxtor Z1 SSD 480GB U  
    ----------------------------------------------------------------------------
    
    EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
    DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
    UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
    Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
    SeSz-Sector Size|Sp-Spun|U-Up|D-Down/PowerSave|T-Transition|F-Foreign
    UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
    CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded
    
    
    
    [root@localhost ~]# 

     

    [root@localhost ~]# ./storcli64 /c0/vall show 
    Controller = 0
    Status = Success
    Description = None
    
    
    Virtual Drives :
    ==============
    
    ---------------------------------------------------------------
    DG/VD TYPE  State Access Consist Cache Cac sCC       Size Name 
    ---------------------------------------------------------------
    0/0   RAID0 Optl  RW     Yes     RWTD  -   ON  446.625 GB      
    ---------------------------------------------------------------
    
    Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded
    Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady|B=Blocked|
    Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
    AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
    Check Consistency
    
    
    
    [root@localhost ~]# ./storcli64 /c0/v0 show 
    Controller = 0
    Status = Success
    Description = None
    
    
    Virtual Drives :
    ==============
    
    ---------------------------------------------------------------
    DG/VD TYPE  State Access Consist Cache Cac sCC       Size Name 
    ---------------------------------------------------------------
    0/0   RAID0 Optl  RW     Yes     RWTD  -   ON  446.625 GB      
    ---------------------------------------------------------------
    
    Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded
    Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady|B=Blocked|
    Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
    AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
    Check Consistency
    
    
    
    [root@localhost ~]#
    6、查看raid组详细信息
     
    查看系统里面有几个raid组:
    [root@localhost storcli]# ./storcli64 /c0/vall  show 【查看c0控制下的所有RAID信息】
    Controller = 0
    Status = Success
    Description = None
     
     
    Virtual Drives :
    ==============
     
    ---------------------------------------------------------------
    DG/VD TYPE  State Access Consist Cache Cac sCC       Size Name
    ---------------------------------------------------------------
    0/0   RAID1 Optl  RW     Yes     RaWBD R   OFF 278.875 GB      
    1/1   RAID5 Optl  RW     Yes     RaWBD R   OFF   4.089 TB      
    2/2   RAID5 Optl  RW     Yes     RaWBD R   OFF   4.089 TB      【显示系统有三个raid组】
    ---------------------------------------------------------------
     
    Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|dgrd=Degraded
    Optl=Optimal|RO=Read Only|RW=Read Write|B=Blocked|Consist=Consistent|
    Ra=Read Ahead Adaptive|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
    AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
    Check Consistency
     
     
     
    查看V0  (虚拟磁盘0) raid的详细信息
    [root@localhost storcli]# ./storcli64 /c0/v0 show all
    Controller = 0
    Status = Success
    Description = None
     
     
    /c0/v0 :
    ======
     
    ---------------------------------------------------------------
    DG/VD TYPE  State Access Consist Cache Cac sCC       Size Name
    ---------------------------------------------------------------
    0/0   RAID1 Optl  RW     Yes     RaWBD R   OFF 278.875 GB      【V0为RAID1】
    ---------------------------------------------------------------
     
    Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|dgrd=Degraded
    Optl=Optimal|RO=Read Only|RW=Read Write|B=Blocked|Consist=Consistent|
    Ra=Read Ahead Adaptive|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
    AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
    Check Consistency
     
     
    PDs for VD 0 :
    ============
     
    -------------------------------------------------------------------------
    EID:Slt DID State DG       Size Intf Med SED PI SeSz Model            Sp
    -------------------------------------------------------------------------
    32:24    24 Onln   0 278.875 GB SAS  HDD N   N  512B ST9300603SS      U  
    32:25    25 Onln   0 278.875 GB SAS  HDD N   N  512B ST9300605SS      U  【可以看到24号和25号盘组成了raid1】
    -------------------------------------------------------------------------
     
    EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
    DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
    UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
    Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
    SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign
     
     
    VD0 Properties :
    ==============
    Strip Size = 64 KB
    Span Depth = 1
    Number of Drives Per Span = 2
    Disk Cache Policy = Disk's Default
    Encryption = None
    Data Protection = None
    Active Operations = None
    Exposed to OS = Yes
    Creation Date = 05-09-2012
    Creation Time = 01:38:23 PM
    Emulation type = None
     
    使用方式
    #查询硬件RAID卡信息
    [root@localhost Linux]# cat /proc/scsi/scsi |more
    
    Attached devices:
    Host: scsi0 Channel: 02 Id: 00 Lun: 00
      Vendor: IBM      Model: ServeRAID M5210  Rev: 4.62
      Type:   Direct-Access                    ANSI  SCSI revision: 05
    
    #解压安装storcli
    unzip ibm_utl_sraidmr_storcli-1.07.07_linux_32-64.zip
    rpm -Uvh storcli-1.07.07-1.noarch.rpm
    
    #设置软连接
    ln -s /opt/MegaRAID/storcli/storcli64 /bin/storcli
    ln -s /opt/MegaRAID/storcli/storcli64 /sbin/storcli
    
    #Raid数量及当前状态
    [root@localhost Linux]# storcli show ctrlcount
    Status Code = 0
    Status = Success
    Description = None
    
    Controller Count = 2
    
    #查询虚拟磁盘大小,raid结构等
    [root@localhost Linux]# storcli /c0 /v0 show
    Controller = 0
    Status = Success
    Description = None
    
    
    Virtual Drives :
    ==============
    
    -----------------------------------------------------------
    DG/VD TYPE  State Access Consist Cache sCC       Size Name 
    -----------------------------------------------------------
    0/0   RAID1 Optl  RW     Yes     RWTD  -   278.465 GB      
    -----------------------------------------------------------
    
    Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|dgrd=Degraded
    Optl=Optimal|RO=Read Only|RW=Read Write|B=Blocked|Consist=Consistent|
    R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
    AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
    Check Consistency
    #可以看出此为RAID1,一个虚拟磁盘,大小为278.465 GB 
    
    #查看control0的物理硬盘
    [root@localhost Linux]# storcli /c0 /eall /sall show
    Controller = 0
    Status = Success
    Description = Show Drive Information Succeeded.
    
    
    Drive Information :
    =================
    
    -------------------------------------------------------------------------
    EID:Slt DID State DG       Size Intf Med SED PI SeSz Model            Sp 
    -------------------------------------------------------------------------
    252:16    8 Onln   0 278.465 GB SAS  HDD N   Y  512B ST300MP0035    X U  
    252:17    9 Onln   0 278.465 GB SAS  HDD N   Y  512B ST300MP0035    X U  
    -------------------------------------------------------------------------
    
    EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
    DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
    UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
    Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
    SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign
    UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
    CFShld-Configured shielded
    
    #可以看到总计有两颗硬盘,每一颗大小278.465GB,是否在线等
    
    #查看control1的物理硬盘
    [root@localhost Linux]# storcli /c1 /eall /sall show
    Controller = 1
    Status = Success
    Description = Show Drive Information Succeeded.
    
    
    Drive Information :
    =================
    
    ------------------------------------------------------------------------
    EID:Slt DID State DG      Size Intf Med SED PI SeSz Model            Sp 
    ------------------------------------------------------------------------
    8:0      23 JBOD  -  1.0810 TB SAS  HDD N   Y  512B ST1200MM0018   X U  
    8:1      24 JBOD  -  1.0810 TB SAS  HDD N   Y  512B ST1200MM0018   X U  
    8:2      22 JBOD  -  1.0810 TB SAS  HDD N   Y  512B ST1200MM0018   X U  
    8:3      19 JBOD  -  1.0810 TB SAS  HDD N   Y  512B ST1200MM0018   X U  
    8:4      13 JBOD  -  1.0810 TB SAS  HDD N   Y  512B ST1200MM0018   X U  
    8:5      14 JBOD  -  1.0810 TB SAS  HDD N   Y  512B ST1200MM0018   X U  
    8:6      18 JBOD  -  1.0810 TB SAS  HDD N   Y  512B ST1200MM0018   X U  
    8:7      12 JBOD  -  1.0810 TB SAS  HDD N   Y  512B ST1200MM0018   X U  
    8:8      10 JBOD  -  1.0810 TB SAS  HDD N   Y  512B ST1200MM0018   X U  
    8:9      16 JBOD  -  1.0810 TB SAS  HDD N   Y  512B ST1200MM0018   X U  
    8:10     11 JBOD  -  1.0810 TB SAS  HDD N   Y  512B ST1200MM0018   X U  
    8:11     21 JBOD  -  1.0810 TB SAS  HDD N   Y  512B ST1200MM0018   X U  
    8:12     15 JBOD  -  1.0810 TB SAS  HDD N   Y  512B ST1200MM0018   X U  
    8:13      9 JBOD  -  1.0810 TB SAS  HDD N   Y  512B ST1200MM0018   X U  
    ------------------------------------------------------------------------
    
    EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
    DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
    UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
    Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
    SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign
    UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
    CFShld-Configured shielded
    
    #可以看到总计有两颗硬盘,每一颗大小1.0810 TB,是否在线等
    
    
    #设置硬盘状态
    storcli /c1/e8/s0 show all
    
    storcli /c1/e8/s0 start locate
    storcli /c1/e8/s0 set offline
    storcli /c1/e8/s0 set online
    storcli /c1/e8/s0 set jbod
    
    StorCLI Help
    #查看StorCLI帮助信息
    [root@localhost Linux]# storcli -h
         Storage Command Line Tool  Ver 1.07.07 Nov 15, 2013
    
         (c)Copyright 2013, LSI Corporation, All Rights Reserved.
    
    
    storcli -v 
    storcli -h| -help| ? 
    storcli -h| -help| ? legacy
    storcli show 
    storcli show all
    storcli show ctrlcount
    storcli /cx add vd r[0|1|5|6|00|10|50|60]
        [Size=<VD1_Sz>,<VD2_Sz>,..|all] [name=<VDNAME1>,..] 
        drives=e:s|e:s-x|e:s-x,y,e:s-x,y,z [PDperArray=x][SED]
        [pdcache=on|off|default][pi][DimmerSwitch(ds)=default|automatic(auto)|
        none|maximum(max)|MaximumWithoutCaching(maxnocache)]
        [wt|wb|awb][nora|ra] [direct|cached] [cachevd]
        [Strip=<8|16|32|64|128|256|512|1024>] [AfterVd=X] 
        [Spares = [e:]s|[e:]s-x|[e:]s-x,y] [force][ExclusiveAccess]
    storcli /cx add vd each r0 [name=<VDNAME1>,..] [drives=e:s|e:s-x|e:s-x,y]
        [SED] [pdcache=on|off|default][pi] [DimmerSwitch(ds)=default|automatic(auto)|
        none|maximum(max)|MaximumWithoutCaching(maxnocache)] 
        [wt|wb|awb] [nora|ra] [direct|cached] 
        [Strip=<8|16|32|64|128|256|512|1024>] [ExclusiveAccess]
    storcli /cx add VD cachecade|nytrocache r[aid][0,1,10, 1EC] 
        drives = [e:]s|[e:]s-x|[e:]s-x,y [WT| WB] [assignvds = 0,1,2] [BOOTVOLSIZE=x]
    storcli /cx/
  • 相关阅读:
    eclipse 异常Unhandled event loop exception
    eclipse序列化生成serialVersionUID
    [转载]给10万pv的WordPress选择最便宜高可用的硬件以及WordPress高并发支持
    struts2日常
    JQuery表格展开与内容筛选
    记一次简单的清理挖矿程序过程
    【原创总结】服务为什么会报404?
    【原创总结】Tomcat进程为什么起不来?
    【原创总结】服务为什么会报500的错误?
    【原创】关于nginx.pid丢失的解决办法
  • 原文地址:https://www.cnblogs.com/dream397/p/13536550.html
Copyright © 2011-2022 走看看