  • 转 OGG-01224 TCP/IP error 111 (Connection refused); retries exceeded.

    https://blog.csdn.net/yabingshi_tech/article/details/40620351

    在源端启动goldengate pump进程,状态起初是running,后来却变成了ABENDED    

    1.  
      GGSCI (source_pc) 3> info all
    2.  
       
    3.  
      Program Status Group Lag at Chkpt Time Since Chkpt
    4.  
       
    5.  
      MANAGER RUNNING
    6.  
      EXTRACT RUNNING EORA_T1 00:00:00 00:00:07
    7.  
      EXTRACT ABENDED PORA_T1 00:00:00 00:12:40
    8.  
       
    9.  
       


    查看错误报告:

    GGSCI (source_pc) 4> view report pora_t1

    看到这个错误:

    2014-10-30 03:02:25  ERROR   OGG-01224  TCP/IP error 111 (Connection refused); retries exceeded.

    2014-10-30 03:02:25  ERROR   OGG-01668  PROCESS ABENDING. 

    --查看pump参数

    1.  
      GGSCI (source_pc) 5> view params pora_t1
    2.  
       
    3.  
      extract pora_t1
    4.  
       
    5.  
      setenv (NLS_LANG=AMERICAN_AMERICA.AL32UTF8)
    6.  
       
    7.  
      passthru
    8.  
       
    9.  
      rmthost 192.168.8.226,mgrport 7809
    10.  
       
    11.  
      rmttrail ./dirdat/pa
    12.  
       
    13.  
      table scott.t;
    14.  
       
    15.  
       
    16.  
       

     --查看源端和目标端mgr参数

    1.  
      GGSCI (source_pc) 6> view params mgr
    2.  
       
    3.  
      PORT 7089
    4.  
       
    5.  
       
    6.  
       
    7.  
       
    8.  
      GGSCI (target_pc) 10> view params mgr
    9.  
       
    10.  
      PORT 7089
    11.  
       
    12.  
       

    发现它们的端口号不一致.

    改成一样的,如都改为7809,然后重启mgr,pump,extract,replicat等相关进程即可