https://blog.csdn.net/yabingshi_tech/article/details/40620351
在源端启动goldengate pump进程,状态起初是running,后来却变成了ABENDED
-
GGSCI (source_pc) 3> info all
-
-
Program Status Group Lag at Chkpt Time Since Chkpt
-
-
MANAGER RUNNING
-
EXTRACT RUNNING EORA_T1 00:00:00 00:00:07
-
EXTRACT ABENDED PORA_T1 00:00:00 00:12:40
-
-
查看错误报告:
GGSCI (source_pc) 4> view report pora_t1
看到这个错误:
2014-10-30 03:02:25 ERROR OGG-01224 TCP/IP error 111 (Connection refused); retries exceeded.
2014-10-30 03:02:25 ERROR OGG-01668 PROCESS ABENDING.
--查看pump参数
-
GGSCI (source_pc) 5> view params pora_t1
-
-
extract pora_t1
-
-
setenv (NLS_LANG=AMERICAN_AMERICA.AL32UTF8)
-
-
passthru
-
-
rmthost 192.168.8.226,mgrport 7809
-
-
rmttrail ./dirdat/pa
-
-
table scott.t;
-
-
-
--查看源端和目标端mgr参数
-
GGSCI (source_pc) 6> view params mgr
-
-
PORT 7089
-
-
-
-
-
GGSCI (target_pc) 10> view params mgr
-
-
PORT 7089
-
-
发现它们的端口号不一致.
改成一样的,如都改为7809,然后重启mgr,pump,extract,replicat等相关进程即可