CtsSecurityTestCases#ListeningPortsTest定位tcp端口与pid
【问题描述】
cts失败项
armeabi-v7a CtsSecurityTestCases
android.security.cts.ListeningPortsTest#testNoListeningLoopbackTcpPorts
工具:9.0_r11
05-06 17:11:28.649 17375 17391 E TestRunner: android.security.cts.ListeningPortsTest$ListeningPortsAssertionError:
05-06 17:11:28.649 17375 17391 E TestRunner: Found port listening on addr=127.0.0.1, port=10100, UID=1000 [com.android.keychain, com.itv.android.iptv, com.android.location.fused, com.android.providers.settings,com.launcher.idn, android, com.itv.android.iptv.tvclient,com.droidlogic, com.android.wallpaperbackup, com.droidlogic.BluetoothRemote, ] in /proc/net/tcp
05-06 17:11:28.649 17375 17391 E TestRunner: at android.security.cts.ListeningPortsTest.assertNoAccessibleListeningPorts(ListeningPortsTest.java:250)
05-06 17:11:28.649 17375 17391 E TestRunner: at android.security.cts.ListeningPortsTest.testNoListeningLoopbackTcpPorts(ListeningPortsTest.java:138)
【问题结论】
定位到subtitle端口监听某次提交,回退后测试pass
AuthBlog:秋城https://www.cnblogs.com/houser0323
【分析详细】
1.定位节点inode
port=10100是十进制,/proc/net/tcp中port是十六进制,做一下转换10110-->2774,见下面2:处,对应inode为32905。
console:/ # cat proc/net/tcp
sl local_address rem_address st tx_queue rx_queue tr tm->when retrnsmt uid timeout inode
0: 7632A8C0:EA60 00000000:0000 0A 00000000:00000000 00:00000000 00000000 1000 0 58215 1 00000000 100 0 0 10 0
1: 00000000:1A85 00000000:0000 0A 00000000:00000000 00:00000000 00000000 0 0 33635 1 00000000 100 0 0 10 0
2: 0100007F:2774 00000000:0000 0A 00000000:00000000 00:00000000 00000000 1000 0 32905 1 00000000 100 0 0 10 0
2.根据inode查找pid
进入/proc/[pid]/fd/目录下ls -l 查看socket端口号,由于我们不知道在哪个pid目录下,所以遍历一下
sh脚本或者终端输入shell命令for循环遍历查找32905节点的pid:
# for dir in `find /proc -name "fd" 2>/dev/null`
> do
> ls -l $dir | grep "socket:[32905]" && echo $dir
> done
结果查找到pid为4085
lrwx------ 1 root root 64 2020-05-07 11:03 46 -> socket:[32905]
/proc/4085/task/4085/fd
lrwx------ 1 root root 64 2020-05-07 11:03 46 -> socket:[32905]
/proc/4085/task/4094/fd
......
lrwx------ 1 root root 64 2020-05-07 10:47 46 -> socket:[32905]
/proc/4085/fd
3.查看pid对应的程序
console:/ # ps 4085
USER PID PPID VSZ RSS WCHAN ADDR S NAME
system 4085 3024 1124392 82892 SyS_epoll_wait 0 S com.droidlogic.SubTitleService
至此定位结束,反馈给相应模块处理
【参考资料】
1.嵌入式设备上如何通过端口号定位到进程
https://blog.csdn.net/daizhongyin/article/details/90031132
2.获取tcp/udp端口对应的进程pid
https://blog.csdn.net/ChrisNiu1984/article/details/7022745