zoukankan      html  css  js  c++  java
  • RPD Volume 168 Issue 4 March 2016 评论4

    Non-vascular interventional procedures: effective dose to patient and equivalent dose to abdominal organs by means of DICOM images and Monte Carlo simulation

     

    Abstract

    This study evaluates X-ray exposure in patient undergoing abdominal extra-vascular interventional procedures by means of Digital Imaging and COmmunications in Medicine (DICOM) image headers and Monte Carlo simulation. The main aim was to assess the effective and equivalent doses, under the hypothesis of their correlation with the dose area product (DAP) measured during each examination. This allows to collect dosimetric information about each patient and to evaluate associated risks without resorting to in vivo dosimetry. The dose calculation was performed in 79 procedures through the Monte Carlo simulator PCXMC (A PC-based Monte Carlo program for calculating patient doses in medical X-ray examinations), by using the real geometrical and dosimetric irradiation conditions, automatically extracted from DICOM headers. The DAP measurements were also validated by using thermoluminescent dosemeters on an anthropomorphic phantom. The expected linear correlation between effective doses and DAP was confirmed with an R2 of 0.974. Moreover, in order to easily calculate patient doses, conversion coefficients that relate equivalent doses to measurable quantities, such as DAP, were obtained.

    通过文章可以知道DICOM的全名师医学数字成像和通信。文章主要做了一些计算和实验,进行了线性拟合等。还进行了转换系数的计算等。文章给的软件名称也可以搜索看看。经过搜索简介如下

    PCXMC is a computer program for calculating patients' organ doses and effective doses in medical x-ray examinations (radiography and fluoroscopy). The doses are calculated in 29 organs and tissues and the program calculates the effective dose with both the present tissue weighting factors of ICRP Publication 103 (2007) and the old tissue weighting factors of ICRP Publication 60 (1991). The program incorporates adjustable-size paediatric and adult patient models and allows a free choice of the x-ray examination technique.

  • 相关阅读:
    Java读书笔记(2)-输入输出
    Java读书笔记(1)-异常处理
    Photoshop自动导出各尺寸Android和Iphone图标,支持新版Android Studio
    【原创】我的研究生活
    [原创]使用Fiddler抓取手机APP流量--360WIFI
    Federa 7 配置yum 源
    开源自己写的刷票器软件(windows和Android)
    更新linux kernel到3.14.10 LTS版后,virt-manager无法识别qemu hypervisor的问题
    Net Core Identity 身份验证:注册、登录和注销 (简单示例)
    Net Core的API文档工具Swagger
  • 原文地址:https://www.cnblogs.com/liq07lzucn/p/5339746.html
Copyright © 2011-2022 走看看