  • VSAN Cluster Failed

    failed message:
    AdVanced vSAN configuration in sync
    Checks if all of the hosts in a vSAN cluster have consistent
    advanced configuration options.

    问题:
    LSOM.blPLOGCacheLines
    LSOM.blPLOGLsnCacheLines
    VSAN.DomMaxLeafAssocsPerHost
    不同ESXi服务器上的上面三个设置的值(value)不一致。

    使用命令修改如下:
    esxcfg-advcfg -s 16384 /LSOM/blPLOGCacheLines
    esxcfg-advcfg -s 1024 /LSOM/blPLOGLsnCacheLines
    esxcfg-advcfg -s 36000 /VSAN/DomMaxLeafAssocsPerHost

    查看方法:
    [root@esxi:~] vsish

    /> cat /config/LSOM/intOpts/blLLOGCacheLines

    Vmkernel Config Option {

    Default value:128

    Min value:16

    Max value:16384

    Current value:128

    hidden config option:1

    Description:Number of cache lines for bucketlist in LLOG (Requires Reboot)

    }

    /> exit