zoukankan      html  css  js  c++  java
  • 取消COM调用word,ppt时显示的正在切换对话框

    http://support.microsoft.com/kb/248019/en-us 

      How to prevent the OLE Server Busy dialog box from appearing during a lengthy COM operation

    View products that this article applies to.
    Article ID : 248019
    Last Review : November 21, 2006
    Revision : 4.1
    This article was previously published under Q248019
    Note Microsoft Visual C++ .NET (2002) supports both the managed code model that is provided by the Microsoft .NET Framework and the unmanaged native Microsoft Windows code model. The information in this article applies only to unmanaged Visual C++ code.
     Back to the top
     
    SUMMARY
    If you call a method on a COM server from an MFC COM client application and if the method takes a long time to process and return back, you won't be able to do anything on the client application and the OLE Server Busy dialog box pops up. This article explains how you can increase the time-out period of the COM call and also shows you how to avoid this dialog box.
     Back to the top
     
    MORE INFORMATION
    Ensure that the MFC client application is calling AfxOleInit() to initialize COM. This is important, because AfxOleInit() also initializes and registers a COleMessageFilter data member in the CWinApp. Alternatively, you can create your own COleMessageFilter object and register that during the startup.
     
    Use
    AfxOleGetMessageFilter()->SetMessagePendingDelay(nTimeout);
                               
    to set the wait period on outgoing COM calls. If the COM call takes longer than nTimeout milliseconds, then the MFC Client application displays the OLE Server Busy dialog box.
     
    Use,
    AfxOleGetMessageFilter()->EnableNotRespondingDialog(FALSE);
                               
    to disable the Not Responding dialog box, which is displayed if a keyboard or mouse message is pending during an OLE call and the call has timed out.
     
    Use
     AfxOleGetMessageFilter()->EnableBusyDialog(FALSE);
                               
    to disable the busy dialog box from appearing after the COM call times out.
     
    Another way to suppress the server busy dialog box is to use OleInitialize and OleUninitialize instead of AfxOleInit in your application.
  • 相关阅读:
    jmeter的基本使用过程
    selenide UI自动化进阶二 pageObject实现页面管理
    Page Object 设计模式介绍
    自动化测试元素查找利器firepath介绍
    selenide 自动化UI测试中Configuration全局配置项目
    selenide 自动化测试进阶一: 查找元素和相关操作
    Selenide 简单实现自动化测试
    python操作MySQL数据库
    一次验证手机号固话号 正则表达式
    算法入门刷题笔记 算法竞赛入门经典++第六章例题 6-6--6-9,6-12,6-14,6-15 树与二叉树
  • 原文地址:https://www.cnblogs.com/tyjsjl/p/2156099.html
Copyright © 2011-2022 走看看