Component: BC-CTS-TMS
当装完系统,STMS第一次进入系统,就报错
The TMS configuration is inconsistent
then check the TMS alert viewer:
Message SET_CODEPAGE_FAILED
Could not start transport control program tp
具体的报错
Errors during distribution of tp configuration
Message no. XT454
Diagnosis
The tp configuration could not be distributed.
System Response
The function terminates.
Procedure
You can find a detailed error message in the TMS Alert Viewer (see TMS Alert Viewer).
Remove the cause of the error and execute the command again.
Message no. XT454
Diagnosis
The tp configuration could not be distributed.
System Response
The function terminates.
Procedure
You can find a detailed error message in the TMS Alert Viewer (see TMS Alert Viewer).
Remove the cause of the error and execute the command again.
yongxiang Fang-08.04.2020 12:03:16
Could not start transport control program tp
Message no. TP608 Diagnosis
There was an attempt to start the transport control program tp using the local RFC interface. An error occurred here.
Error code: 4
RFC error text: timeout during allocate / CPIC-CALL: 'ThSAPCMRCV',
Meaning of the error codes:
03 RFC system failure
04 RFC communication failure
System Response
The function terminates. Details about the error can be found in the trace file of the Gateway Monitor (SMGW).
Procedure
Contact your system administrator or use report RSTPTEST to localize the error. You can then execute the command again.
Could not start transport control program tp
Message no. TP608 Diagnosis
There was an attempt to start the transport control program tp using the local RFC interface. An error occurred here.
Error code: 4
RFC error text: timeout during allocate / CPIC-CALL: 'ThSAPCMRCV',
Meaning of the error codes:
03 RFC system failure
04 RFC communication failure
System Response
The function terminates. Details about the error can be found in the trace file of the Gateway Monitor (SMGW).
Procedure
Contact your system administrator or use report RSTPTEST to localize the error. You can then execute the command again.
Solution:
set the profile parameter "rfc/use_gwstart = 1"
2173569 - Error when opening an RFC connection