1、Request message:

Sub-function parameter:
0x2F服务不支持sub-function参数。
2、Positive response message:

3、Supported negative response codes (NRC_):

4、Example #1 - ”Air Inlet Door Position” shortTermAdjustment:
Step #1: ReadDataByIdentifier
Request:
0x727 03 22 9B 00 [00 00 00 00]

Positive response:
0x7A7 04 62 9B 00 0A [00 00 00]

Step #2: shortTermAdjustment
Request:
0x727 05 2F 9B 00 03 3C [00 00]

Positive response:
0x7A7 04 62 9B 00 0A [00 00]

Step #3: ReadDataByIdentifier
Request:
0x727 03 2F 9B 00 [00 00 00 00]

Positive response:
0x7A7 04 62 9B 00 3C [00 00 00]

Step #4: returnControlToECU
Request:
0x727 04 2F 9B 00 00 [00 00 00]

Positive response:
0x7A7 05 9B 00 00 3A [00 00 00]

Step #5: freezeCurrentState
Request:
0x727 04 2F 9B 00 02 [00 00 00]

Positive response:
0x7A7 05 6F 9B 00 02 32 [00 00]