zoukankan      html  css  js  c++  java
  • Catalyst 2960 重启?

    在实际的网络环境中,交换机的各种问题层出不穷,这里我遇到一个案例。关于Cisco 2960  S 交换机重启的问题。

    故障描述:有那么几台C2960S交换机总是随机的重启。

    原因:从show ver来看,可以看到是由于power-on。

    实际问题:而实际导致交换机重启的原因并不是power-on,甚至这里没有一个crashinfo的生成。

    关于这个问题,在思科官网能找到类似的问题,但是是一个bug:

    2960S silent reload with "System returned to ROM by power-on"
    CSCtr78622
     
    Description
    Symptom:

    A 2960S may reload without generating a crash file and reload reason is
    reported as "System returned to ROM by power-on".

    Conditions:

    This issue is observed in Catalyst 2960S platform running 12.2(53)SE2.

    Workaround:

    None.

    This bug is under investigation.

    Further Problem Description:

    CSCtg09555 should report more detailed reload information.
     

    问题延伸,该问题可能不只是C2960S的问题,其他的型号也有类似的问题,例如如下的Bug:

    2960x randomly reloads due to power-on
    CSCus47446
     
    Description
    Symptom:
    Catalyst 2960x may reboot randomly and come up. This can happen when switch is a stack member or standalone. When part of stack as a member, entire stack does not go down when a member reloads, but everything connected to the 2960x that reloaded experiences an outage.

    There is no crashinfo written. Reload reason is "power-on".

    Conditions:
    Only PoE models are affected.

    Workaround:
    None.

    Further Problem Description:
    终结的意思可能是该问题已经通过换硬件解决了,没有通过配置或者软件的升级去解决这个问题。
     
    2960x FPS48 randomly reloads due to power-on
    CSCuu90830
     
    Description
    Symptom:
    Catalyst 2960x may reboot randomly and come up. This can happen when switch is a stack member or standalone. When part of stack as a member, entire stack does not go down when a member reloads, but everything connected to the 2960x that reloaded experiences an outage.

    There is no crashinfo written. Reload reason is "power-on".

    Conditions:
    The switch that reloaded is a PoE capable 2960X

    Workaround:
    None.

    Further Problem Description:
    This could be a hardware issue, please contact Cisco TAC for further analysis.
     
    这应该算是一个严重的错误了。不知该问题后续是否有fixed版本。