zoukankan      html  css  js  c++  java
  • minicom无法输入问题

    在使用minicom查看log时候,今天发现无法回车进入到命令行模式输入命令了,通过查找资料发现关键点就在串口的配置中有个Serial port setup-->Hardware Flow Contorl选项被改成了Yes,这样就造成了键盘没有用了,接受不了任何输入。把他改成No就好了。具体修改操作如下:

    sudo minicom -s

    +-----[configuration]------+
    | Filenames and paths |
    | File transfer protocols |
    | Serial port setup |
    | Modem and dialing |
    | Screen and keyboard |
    | Save setup as dfl |
    | Save setup as.. |
    | Exit |
    | Exit from Minicom |
    +--------------------------+

    进入Serial port setup界面

    +-----------------------------------------------------------------------+
    | A - Serial Device : /dev/ttyS1 |
    | B - Lockfile Location : /var/lock |
    | C - Callin Program : |
    | D - Callout Program : |
    | E - Bps/Par/Bits : 115200 8N1 |
    | F - Hardware Flow Control : No |
    | G - Software Flow Control : No |
    | |
    | Change which setting? |
    +-----------------------------------------------------------------------+

    此时F - Hardware Flow Contorl项为Yes,按下F键就修改为No了,即关闭硬件流控,回车回到上级菜单

    +-----[configuration]------+
    | Filenames and paths |
    | File transfer protocols |
    | Serial port setup |
    | Modem and dialing |
    | Screen and keyboard |
    | Save setup as dfl |
    | Save setup as.. |
    | Exit |
    | Exit from Minicom |
    +--------------------------+

    选择| Save setup as dfl |,然后选择 Exit from Minicom  重启minicom

    这样就可以输入命令了。