zoukankan      html  css  js  c++  java
  • 服务器RAID维护相关资料

    原创作品,允许转载,转载时请务必以超链接形式标明文章 原始出处 、作者信息和本声明。否则将追究法律责任。http://liubin.blog.51cto.com/282313/116046
    DELL PowerEdge 2950 服务器RAID维护相关资料
    DELL 服务站点:[url]www.dell.com.cn[/url]
    PowerEdge 800 电话:800-858-0960
    服务器编号:4KMNH2X
    快速服务编码:9954499641
    硬盘槽位:0,1,2,3,4,5
    带光驱
    操作系统:RHEL5 ,做RAID后,安装RHEL5,不用在手动加载RAID驱动
    ----------
    开机后,部分提示信息(本提示信息是RAID相关部分,可能出现的部分状况)
    press ctrl+R to run configuration utility
    HA-0 (Bus 1 Dev 0) PERC 6/i integrated
    Fw package:6.0.2--0002
    2 virtual Driver(s) found on the host adapter
    1 virtual Driver(s) Degraded
    2 virtual Driver(s) handled by BIOS
    foreign configuration(s) found on adapter
    press any key to continue or 'C' load the configuration utility or 'F' to import foreign configuration (s) and continue
    按CTRL+R 后出现的界面大致如下:
    PERC 6/i integrated BIOS configuration utility
    VD mgmt PD mgmt Ctrl mgmt Foreign view
    -----
    F1- help F2-operation F5-Refresh Ctrl-N -Nextpage Ctrl -p prev-page F12-ctlr
    常用选项内容:
    VD 
      controller0
           diskgroup 0
               virtual disk 1
               physical disk 
                  --:--:04
               space allocation
                  virtual disk 1
               hot spares
           diskgroup 1
               ........
               ........
               ........
               ........
    PD mgmt
    prive ID Vendor size/mb type state DG
    --:--:0 ATA xxxxx xxxx online 01
    --:--:1 ATA xxxxx xxxx online 01
    --:--:2 ATA xxxxx xxxx foreign
    --:--:3 ATA xxxxx xxxx rebuild
    --;--:4 ATA xxxxx xxxx online 02
    在以下选中位置按F2后,出现的内容:
    controller 0
    create new VD
    reset config
    foreign config -----> import
    clear
    disk group 0
    manage Ded .HS----> Dedicated Hotspare for disk group 0
    Delete Disk group
    virtual disk 0
    initialization
    consistency check
    delete VD
    properties
    PD mgmt 页面中,选中某行后,
    rebuild
    CED blinking
    force online
    force offline
    make global HS
    remove hot spare
    --------------------------
    故障实例:
    1、RAID5 一块硬盘掉线
    2950 在0,1,2 三个硬盘槽位分别接入了 ST 1TB SATA 硬盘,配置成RAID 5 。
    开机后发现有一块硬盘指示灯不亮,显示器上并提示如下:
    some configured disks have been removed from your system or are no longer accessible.
    please check you cables and also ensure all disk are present.press any key to continue,or
    'C' to load the configuration utility.
    按 键盘 上的 C 键后,出现提示如下:
    Entering the configuration uility in this state will result in drive configuration changes .press 'Y' to continue loading the configuration utility or power off your system
    and check your cables to ensure all disk are present and reboot
    按 键盘 上的 Y 键后
    进入RAID配置界面,没有看到在1 号位的 硬盘,提示:MISSING ,RAID 5 状态为
    Degraded
    然后重启机器后,发现 原来指示灯不亮的硬盘,指示灯开始变为橙色,后又变成绿色
    提示:
    Fw package:6.0.2--0002
    2 virtual Driver(s) found on the host adapter
    1 virtual Driver(s) Degraded
    2 virtual Driver(s) handled by BIOS
    foreign configuration(s) found on adapter
    press any key to continue or 'C' load the configuration utility or 'F' to import foreign configuration (s) and continue
    然后,在RAID配置界面里将掉线的,导入。后恢复正常后,不久该硬盘又掉线,怀疑硬盘有问题。导入的时间将近4个小时,数据量2G多,硬盘上就光一个RHEL5 定制的系统
    --------------
    RAID 5 更换1块坏硬盘。0,1,2 三块插槽位配置RAID5 。1插槽位的驱动器状态由绿变橙。预报警。现更换1 处的硬盘。
    方法1、
    在开机状态,机器正常运行情况下,取下有问题的硬盘后,在接入新的同型号,同容量大小的硬盘,此时,可观察到,0,3 插槽位的硬盘指示状态灯亮绿色,活动状态灯绿色闪烁。1插槽位硬盘指示状态灯绿色闪烁,活动状态灯不亮。此时,1 插槽位的硬盘正在重建数据。等0,1,2 驱动器硬盘指示状态等全绿,稳定亮起时。RAID 5 重建完成
    方法2、
    关机,取下坏硬盘。在接入新的同型号,同容量大小的硬盘。开机,后 进入 RAID的配置界面,在 手工 重建 新硬盘的数据
  • 相关阅读:
    linux共享内存的命令
    css元素类型
    不争万年,只珍朝夕我对编程的态度
    Oracle读书笔记PL/SQL编程(二)之程序流程
    oracle读书笔记PL/SQL编程(一)之基本数据类型、程序结构
    关于解决oracle登录:ora12154:tns:无法解析指定的连接标识符
    Hibernate读书笔记hibernate第一个案例的分析
    Oracle读书笔记PL/SQL编程(三)之游标
    解决jscollpan不能出现水平滑动条的问题
    关于org.hibernate.exception.SQLGrammarException: could not insert:
  • 原文地址:https://www.cnblogs.com/mrhgw/p/2193982.html
Copyright © 2011-2022 走看看