  • OceanStor SNS2124光纤口指示灯不亮

    问题描述

    某局点两台SNS2124光纤交换机连接华为5600 V3存储,客户反映其中一台SNS2124所有指示灯都不亮。

    告警信息

    NA

    处理过程

    1.确认光模块,光纤线,存储接口卡等配置无问题。

    2.更换其他光模块,多模光纤线,接口卡,SNS2124光交接口卡指示灯依旧不亮。

    3.通过switchshow命令显示交换机状态:

    SNS2124_2:admin> switchshow
    switchName:     SNS2124_2
    switchType:     71.2
    switchState:    Offline  (Persistent)
    switchMode:     Native
    switchRole:     Disabled
    switchDomain:   1 (unconfirmed)
    switchId:       fffc01
    switchWwn:      10:00:c4:f5:7c:6d:3f:bc
    zoning:         ON (ABC)
    switchBeacon:   OFF

    对比正常的SNS2124 swithshow显示交换机状态:

    SNS2124_1:admin> switchshow
    switchName:     SNS2124_1
    switchType:     71.2
    switchState:    Online  
    switchMode:     Native
    switchRole:     Principal
    switchDomain:   1
    switchId:       fffc01
    switchWwn:      10:00:c4:f5:7c:73:02:c8
    zoning:         ON (ABC)
    switchBeacon:   OFF

    4.通过命令:switchcfgpersistentenable开启端口后,交换机工作正常。

    根因

    经与客户沟通了解,机器之前有发生过异常掉电,掉电是一个异常的关机操作,在上电后可能会概率导致交换机进入persistentdisable状态,使用命令开启就可以恢复了。

    解决方案

    通过命令:switchcfgpersistentenable开启端口

    建议与总结

    掉电是一个异常的关机操作,建议通过命令:sysshutdown下电光交。

    转自:https://support.huawei.com/enterprise/en/knowledge/KB1000525697