  • VPW Communication Protocol

    http://www.fastfieros.com/tech/vpw_communication_protocol.htm

    Breakdown of the j1850 3 byte Header format

    Byte1 = priority


    Bits 7,6 and 5 are priority 0=High, 7=Low

    Bit 4 is header style (0=3 byte header-GM, 1=1 byte header-??)

    Bit 3 is In Frame Response (0=Required-Ford, 1=Not allowed-GM)
    Bit 2 is addressing mode (1=Physical, 0=Functional)
    Bit 1,0 is message type: (depending on bit 2 and 3 see below)

    Bit 3 2 1 0
    -----------
    Functional

    1 0 0 0 Function
    1 0 0 1 Broadcast
    1 0 1 0 Query
    1 0 1 1 Read

    Physical

    1 1 0 0 Node to Node
    1 1 0 1 Reserved
    1 1 1 0 Reserved
    1 1 1 1 Reserved

    Byte2 = physical ID of destination

    Byte3 = physical ID of source 

    Typical Physical ID's, PCM = $10, Off-board scan tool = $F1

    Header Byte 

    $48 : 001-0-1-0-00 : Priority 1, 3 byte header,  In Frame Response Not Alloed ( GM), Functional Addressing

    $68 : 011-0-1-0-00 : Priority 3, 3 byte header,  In Frame Response Not Alloed ( GM), Functional Addressing

    $6C : 011-0-1-1-00 : Priority 3, 3 byte header,  In Frame Response Not Alloed ( GM), Physical Addressing


    Functional Addresses:

    ID           Function
    -----       ----------------------------
    $6A       Request Legislated Diagnostics (bit 0 (W bit) = 0 Command)
    $6B       Report Legislated Dianostics (bit 0 (W bit) = 1 Status)

    Request current value of PID ($00..$20)

    Send: $68,$6A,$F1 :$01,$PID

    Recv: $48,$6B,$10 : $41,$PID,[up to 5 data bytes]


    Physical Node Addresses:

    ID                 Module
    ---------       ----------------------------
    $00-$1F Powertrain controllers

    $00-$0F Integration/Manufacturer Expansion
    $10-$17 Engine controllers
    $18-$1F Transmission controllers

    $20-$3F Chassis controllers

    $20-$27 Integration/Manufacturer Expansion
    $28-$2F Brake controllers
    $30-$37 Sterring controllers
    $38-$3F Suspension controllers

    $40-$C7 Body controllers

    $40-$57 Integration/Manufacturer Expansion
    $48-$5F Restraints
    $60-$6F Driver information/Diplays
    $70-$7F Lighting
    $80-$8F Enterntainment
    $90-$97 Personal communications
    $98-$9F Climate control (HVAC)
    $A0-$BF Convenience (doos, Seats, Windows, etc.)
    $C0-$C7 Security

    $C8-$CB Electric Vehicle Energy Transfer System (EV-ETS)

    $C8 Utility connection services
    $C9 AC to AC conversion
    $CA AC to DC conversion
    $CB Energy storage management

    $CC-$CF Future expansion

    $D0-$EF Manufacturer specific

    $F0-$FD Off-Board Testers/Diagnostic scan tools

    $FE All nodes

    $FF Null node

    Examples of VPW Code (Functional Messages)
    For the OBDII mandated diagnostics, requsts are actually made to the functional address $6A,
    with whatever processor is responsible for this function answering the request.
    Theoretically many different processors can respond to a single functional request,
    each contributing their insight as to the information requested.

    Request current value of PID ($00..$20):

    • Send: $68,$6A,$F1,$01,$PID
    • Recv: $48,$6B,$10,$41,$PID,[up to 5 data bytes]

    Request freeze frame value of PID ($00..$20):

    • Send: $68,$6A,$F1,$02,$PID,$FRAME
    • Recv: $48,$6B,$10,$42,$PID,$FRAME,[up to 5 data bytes] 
      where FRAME is $01..$06 and is the freeze frame number from which to retrieve the PID's history data.


    Examples of VPW Code (Physical Messages)

    Request GM VIN:

    • Send: $6C,$10,$F1,$3C,$01
    • Recv: $6C,$F1,$10,$7C,$01,[VIN segment 1 data]
    • Send: $6C,$10,$F1,$3C,$02
    • Recv: $6C,$F1,$10,$7C,$02,[VIN segment 2 data]
    • Send: $6C,$10,$F1,$3C,$03
    • Recv: $6C,$F1,$10,$7C,$03,[VIN segment 3 data]

    Request GM PCM#:

    • Send: $6C,$10,$F1,$3C,$04
    • Recv: $6C,$F1,$10,$7C,$04,[PCM #, 4 data bytes]

    Request enhanced PID ($0000..$FFFF):

    • Send: $6C,$10,$F1,$22,$PID-hsb,$PID-lsb,$01
    • Recv: $6C,$F1,$10,$62,$PID-hsb,$PID-lsb,[up to 5 data bytes]


    Requesting a DTC

    The $XX byte in the following command: $6C,$10,$F1,$19,$XX,$FF,$00 
    is the status byte. It has the following "bitmapped" values:

    • $80 - MIL is illuminated
    • $40 - Pending trouble code
    • $20 - Old code - MIL was illuminated for this code but is no longer illuminated.
    • $10 - History code with freeze frame data available.
    • $08 - Manufacturer specific status (I do not know what this means).
    • $04 - Manufacturer specific status (I do not know what this means).
    • $02 - Current code.
    • $01 - Immature code.

    To get real trouble codes you should request only
    $80+$10+$02=$C2

    To get real trouble codes AND pending trouble codes request:
    $80+$40+$10+$02=$D2