    此责任无可用函数(The Function Is Not Available Under The Responsibility)

    When attempting to navigate to a function which has been newly added to a menu the following error occurs:

    ERROR

    The <Function Name> Function Is Not Available Under The <Responsibility Name> Responsibility

    STEPS

    The issue can be reproduced at will with the following steps:

    1. Query menu: <Menu Name>,

    2. Add function: <Function Name> and Save.

    3. Verify that the menu compilation request (FNDSCMPI module: Compile Security) completed successfully.

    4. Log into e-Business Suite and try to navigate to function: <Function Name>.

    5. The error occurs.

    This issue is caused by launching the menu item before the Compile Security has completed. When a function is added to a menu , a concurrent program ‘Compile Security’ is submitted which loads the data in Fnd_Compiled_Menu_Functions table. Whenever a function is accessed, security code checks Fnd_Compiled_Menu_Functions table to determine whether that function is accessible under the given security context or not. So if this function is accessed before the ‘Compile Security’ program is finished, the function cache gets loaded with stale data and the reported error message is thrown.

    So after modifying the 2 menu definitions associated with ‘System Administrator’ and ‘Application Developer’ make sure that 2 concurrent requests submitted for the above 2 modifications completed normally and then try to access the functions.

    Further once this error occurs, it will be cached which means that even after the menu item has been flagged as available, it the error will be returned from the cache.

    — Solution —–

    – To implement the solution, please execute the following steps::

    1) Manually run the ‘Compile Security’ concurrent program, set the parameter to YES.  运行请求  编译安全性

    2) Shut down Middle Tier (Apache)

    3) Delete the contents of $OA_HTML/_pages directory (11.5.10 only).

    4) Restart Middle tier

    5) Test the menu item

    是由于$CUX_TOP没设置引起的,解决方法:

    1.打开$CONTEXT_FILE(即/ebs12/VIS/inst/apps/VIS_erp/appl/admin/VIS_erp.xml)

     找到GL_TOP子句,在它后面加上

    <CUX_TOP oa_var="s_cuxtop" oa_type="PROD_TOP" oa_enabled="FALSE">/ebs12/VIS/apps/apps_st/appl/cux/12.0.0</CUX_TOP>

    2.到$ADMIN_SCRIPTS_HOME(即apache脚本运行目录:/ebs12/VIS/inst/apps/VIS_erp/admin/scripts),重新配置

    adautocfg.sh apps/apps

  • 相关阅读:
    团体程序设计天梯赛-练习集L1-002. 打印沙漏
    WUOJ-ACM :1003: 零起点学算法78——牛牛
    ZOJ-2965
    天梯赛-L1-018. 大笨钟
    代码哲学 摒弃“够用就行”的心态
    github 源码阅读
    Biopython SeqIO 读取序列文件,读取信息,写入序列
    Biopython 模块处理Seq序列 方法
    coursera 有比较丰富的生物信息等课程 win7 访问设置
    python 正则匹配 csv文件中特殊符号如■高风险 这样的black block
  • 原文地址:https://www.cnblogs.com/toowang/p/10648393.html
Copyright © 2011-2022 走看看