  • 对数据集“dsArea”执行查询失败。 (rsErrorExecutingCommand),Query execution failed for dataset 'dsArea'. (rsErrorExecutingCommand),Manually process the TFS data warehouse and analysis services cube

    错误提示:

    处理报表时出错。 (rsProcessingAborted)
    对数据集“dsArea”执行查询失败。 (rsErrorExecutingCommand)
    Team System 多维数据集或者不存在,或者未经处理。

    解决方法:

    Manually process the TFS data warehouse and analysis services cube

    When you need the freshest data in your reports, when errors have occurred, or after you’ve resolved schema conflicts, you can manually process the Team Foundation Server (TFS) relational database (Tfs_Warehouse) or SQL Server Analysis Services cube (Tfs_Analysis).

    During typical operations, the warehouse is processed within two minutes of changes made to an operational store, and the cube is processed every two hours. By manually processing the warehouse, you help ensure that queries and reports are up-to-date with data that depends on the warehouse.

    You use the Warehouse Control Web Service to process the warehouse or cube or perform other maintenance operations. If you know that you want to perform a full rebuild of both databases, then use the Administration consoleor the TFSConfig RebuildWarehouse command.

    Warehouse Control Web Services page

    Note: Do not use SQL Server Management Studio (SSMS) to manually process the cube. Processing the cube using that tool is not supported.

    Process the warehouse or cube

    Processing the warehouse or cube depends on how much data is involved; it can take minutes or hours. Before you process either database, determine the processing status for the synchronization job or jobs that you want to run. Make sure that the status returns Idle

    To access the web services

    1. If you aren’t a member of the Administrators security group on the application-tier server for TFS, get added now.

      Also, make sure that your server-level Administer warehouse permission must be set to Allow.

    2. Log on to the application-tier server and open the Warehouse Control Web Service by entering the following URL in a supported web browser:

      http://localhost:8080/tfs/TeamFoundation/Administration/v3.0/WarehouseControlService.asmx

      If another name was used other than tfs for the virtual directory, then type the IIS Virtual Directory that was specified when Team Foundation Server was installed.

    3. The WarehouseControlWebService page opens.

      If the page doesn’t open, verify that the Microsoft Team Foundation Server Application Pool is running.

    To check the process status

    Choose GetProcessingStatus.

    Get processing status

    A new browser window opens. It indicates the following job’s processing status:

    • Common Structures Warehouse Sync
    • Full Analysis Database Sync
    • Incremental Analysis Database Sync

    And, the status for the following jobs for each team project collection are provided:

    • Build Warehouse Sync
    • Common Structures Warehouse Sync
    • Test Management Warehouse Sync
    • Version Control Warehouse Sync
    • Work Item Tracking Warehouse Sync

    A value of Idle indicates that the synchronization job is currently not running. You should process the data warehouse or the cube only when the processing status for these jobs is Idle. If a different value is returned, repeat this step untilIdle is returned for the job that you want to process.

    To process the data warehouse

    1. Choose ProcessWarehouse, and optionally specify the team project collection to process. If you leavecollectionName blank, all collections are processed.

      The service returns True when it successfully starts the processing of the warehouse and False if it is not successful. A value of False indicates that the warehouse is currently being processed.

    2. To determine the processing status of the warehouse choose GetProcessingStatus as described earlier in tocheck the process status.

      Warehouse processing is completed when the GetProcessingStatus service returns a value of Idle, and a value ofSucceeded for Common Structures Warehouse Sync and for each warehouse for each team project collection.

    To process the Analysis Services cube

    1. Choose ProcessAnalysisDatabase.

    2. For processingType, type either Incremental or Full.

      If you specify Incremental, data is processed only if it has been added since the most recent processing.

      If you specify Full, all data is processed as if the warehouse were being rebuilt. Full processes take longer to perform and should be performed only when required (for example, when a team project or project collection has been removed or deleted).

      The service returns True when it successfully starts the processing of the cube and False if it is not successful. A value of False indicates that the cube is currently being processed.

    3. To determine the processing status of the warehouse choose GetProcessingStatus as described earlier in to check the process status.

      Cube processing is completed when the GetProcessingStatus service returns a value of Idle, and a value ofSucceeded for the following jobs.

      • Full Analysis Database Sync
      • Incremental Analysis Database Sync

    Process dimensions for expanded capacity

    You should run the ProcessDimensionsForExpandedCapacity web service when you receive the following error message:

    Microsoft.TeamFoundation.Warehouse.WarehouseException: TF221122: An error occurred running job Full Analysis Database Sync for team project collection or Team Foundation server TEAM FOUNDATION.  
    
    Microsoft.TeamFoundation.Warehouse.WarehouseException: Failed to Process Analysis Database 'Tfs_Analysis'.  
    
    You should run the ProcessDimensionsForExpandedCapacity web service when you receive the following error message: 
    Microsoft.TeamFoundation.Warehouse.WarehouseException: TF221122: An error occurred running job Full Analysis Database Sync for team project collection or Team Foundation server TEAM FOUNDATION.
    Microsoft.TeamFoundation.Warehouse.WarehouseException: Failed to Process Analysis Database 'Tfs_Analysis'. 
    Microsoft.TeamFoundation.Warehouse.WarehouseException: File system error: A string store or binary store with a compatibility level of '1050' is at the maximum file size of 4 gigabytes. To store additional strings, you can change the StringStoresCompatibilityLevel property of the associated dimension or distinct count measure to '1100' and reprocess. This option is only available on databases with a compatibility level of '1100' or higher.
    Physical file: \?I:OLAPDataTfs_Analysis.0.dbvDimWorkItemOverlay.5.dim7.WorkItemSK.asstore.
    

    This service changes the StringStoresCompatibilityLevel to 1100 for the Version Control File dimension and performs a full cube reprocess.

    1. From the Warehouse Control Web Service, choose ProcessDimensionsForExpandedCapacity.

    2. Enter the name of the dimension. From the above error message, the dimension name is vDimWorkItemOverlay.

    3. The service returns True when it successfully resets the value to 1100.

      Wait until the cube processing has succeeded.

    You should process a database manually for one of the following reasons:

    • Incrementally process the cube when reports don’t show the latest data and you need them up-to-date for an upcoming meeting.
    • Process each team project collection within the data warehouse to verify resolution of all schema conflicts.
    • Process each team project collection within the data warehouse to collect information to diagnose issues appearing in the event viewer related to warehouse jobs.

    Perform a full rebuild of the warehouse and cube when you move, restore, rename, or fail over the TFS data-tier server.

    As needed, change the refresh processing interval or other processing parameters.

     原文:https://www.visualstudio.com/docs/report/admin/manually-process-data-warehouse-and-cube

  • 相关阅读:
    MySQL优化
    右键菜单怎样添加“在此处打开命令提示符”选项
    MemSQL与MySQL不兼容问题总结
    Ubuntu Server 18.04 修改网路配置
    How to Install MemSQL
    Metro UI 菜单(Winform)
    Windows Server 2008 系统设置集合
    推荐个好东西swoole,php如虎添翼
    php的swoole扩展中onclose和onconnect接口不被调用的问题
    关于编程语言(转/收藏)-原文作者:韩天峰(Rango)
  • 原文地址:https://www.cnblogs.com/zjoch/p/5700916.html
Copyright © 2011-2022 走看看